Corrective Maintenance6.5.21. Point Detector Contact GroupTable 6–33. Point Detector Contact Group Maintenance ProcedureStepAction1 NOTEFor removal of contact group, see Table 6–10.Wipe dust from all contacts by using a clean cloth. Cleaning solvent shouldnot be needed for the removal of dust from individual contacts.2 Use light oil to lubricate the motor and shunt contact pivot pins (1). Do notlubricate any other part of the point detector contacts.P1293, Rev. Jun/07 6–75 <strong>Alstom</strong> Signaling Inc.