InstallationTable 3–2. Connect and Initially Adjust Point Detector Connector Rod Procedure(Cont.)StepAction6 After adjustments in both directions, crank machine back and forth a fewtimes to check that locating notches return to proper position at end of eachthrow-bar stroke.NOTELocating notches on point detector rod indicate rollers of thepoint detector yoke are centered in the semicircular notches ofthe point detector rod. Final adjustments must be made inaccordance with AREMA or railroad instructions.P1293, Rev. Jun/07 3–10 <strong>Alstom</strong> Signaling Inc.