Corrective Maintenance6.5.13. Point Detector Rod Wear PlateTable 6–25. Point Detector Rod Wear Plate Maintenance ProcedureStepAction1 NOTEFor point detector rod wear plate disassembly and reassembly,see Table 6–7.Clean point detector rod wear plates of any dirt, grease, or oil by usingapproved cleaning solvent.Replace if excessive wear is evident.2 Install point detector rod wear plates, using grease to lubricate all surfacesaffected by point detector rod sliding action.P1293, Rev. Jun/07 6–69 <strong>Alstom</strong> Signaling Inc.