Corrective MaintenanceTable 6–47. Mechanical Test Procedure (Cont.)StepAction5 Verify there is a minimum of 1/32 inch clearance between the moveable armof the point detector (9) and the cam slot of the cam bar (1). Measure theclearance when the arm is in the vertical position.96 Verify that there is no unnecessary friction in the movable arm (9) of thepoint detector by observing the point detector operation.The movable arm should move without hesitation at the end of eachdirection of stroke.P1293, Rev. Jun/07 6–87 <strong>Alstom</strong> Signaling Inc.