Corrective Maintenance6.4.4. Point Detector ContactTable 6–10. Point Detector Contact Disassembly and Assembly ProcedureStepAction1 Remove the two retaining screws (22 and 23) and their washers holding thecontact stop (18) and U-spring (20) to the contact block on the normal andreverse contacts. Remove the U-spring.MOTORCONTROLCONTACTSNORMAL ANDREVERSECONTACTSNORMAL ANDSHUNT REVERSECONTACTS CONTACTS12345678157A-FOR MODELS <strong>5E</strong> AND <strong>5F</strong> SWITCHMACHINES231822272829213132161730MOTOR CONTROL CONTACTS192021222333 545556NORMAL AND REVERSE CONTACTS21252624 20SHUNT CONTACTSMOTORCONTROLCONTACTSNORMAL ANDREVERSECONTACTSSHUNTCONTACTS1234562323157B-FOR MODELS <strong>5G</strong> AND <strong>5H</strong> SWITCHMACHINES2227282131321617302933545556MOTOR CONTROL AND SHUNT CONTACTS181921222320NORMAL AND REVERSE CONTACTSP1293, Rev. Jun/07 6–54 <strong>Alstom</strong> Signaling Inc.