Scheduled Maintenance4.11.2. Blocking Rectifier TestTable 4–27. Blocking Rectifier Test ProcedureStepAction1 Locate the blocking rectifiers connected between the coils of each biasedneutralcontactor to protect it against the effects of lightning.2 Place a milli-ammeter in the control circuit.3 Check current. It should not exceed 0.025-ampere when the machine is fullyover and locked.4 Change switch position to alternate correlation (Normal to Reverse)5 Check current. It should not exceed 0.025-ampere when the machine is fullyover and locked.6 If the current is too high replace the rectifier.P1293, Rev. Jun/07 4–51 <strong>Alstom</strong> Signaling Inc.