InstallationTable 3–5. Point Detector Rod Adjustment ProcedureWithout Releasing Narrow-Notched Lock Rod (Cont.)StepAction11 Push detector rod toward track.12 Place gauge over rod between rod lug and track-side nuts.13 Retighten machine-side nuts against rod lug with gauge in place.14 Verify that the point-detector contacts have a 0.060 to 0.070 inch opening. Ifso, go to step 15; otherwise, proceed as follows:If contacts open more that 0.070 inch, go to field (opposite) end of detectorrod, loosen field-side nuts and tighten machine-side nuts until properadjustment is obtained. Retighten field-side nuts, then snug machine-sidenuts securely. Return to track end of detector rod.If opening is less than 0.060 inch or closed, go to field (opposite) end ofdetector rod, loosen machine-side nuts and tighten field-side nuts untilproper adjustment is obtained. Retighten machine-side nuts, then snug fieldsidenuts securely. Return to track end of detector rod.15 At track-side of the detector rod, slightly loosen the machine-side nuts,remove gauge and retighten machine-side nuts, again taking care not todisturb track side nuts.P1293, Rev. Jun/07 3–14 <strong>Alstom</strong> Signaling Inc.