Corrective MaintenanceTable 6–12. Cleaning and Lubrication Index (Cont.)<strong>Switch</strong> Machine PartMaintenance ActionTableCleanLubricate16. Point Detector -- -- --a. Contact Group YES YES 6–33b. Contact Movement YES YES 6–34c. Insulation Block YES NO 6–3517. Arm (Clips) YES NO 6–3618. Lock Rod YES YES 6–3719. Point Detector Rod YES YES 6–3820. Throw Bar YES YES 6–3921. Contact Frame YES YES 6–4022. Gear Frame YES YES 6–4123. Main Bed Frame YES YES 6–4224. Cam Bar YES YES 6–4325. Cable Harness YES NO 6–4426. Conduit Coupling YES NO 6–45The following procedures are separated according to individual parts of switch machine.NOTEWhen lubricating switch machine parts, always wipe off excess greaseand oil. Keep grease and oil away from all electrical contacts and wire.WARNINGDO NOT CLEAN OR LUBRICATE MACHINE WHILE ELECTRICALPOWER IS CONNECTED TO PREVENT POTENTIAL PERSONALINJURY OR EQUIPMENT DAMAGEP1293, Rev. Jun/07 6–58 <strong>Alstom</strong> Signaling Inc.