12.07.2015 Views

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 4. Reference Materials EN | 108Table 40: Control Panel Events and Reporting Formats (continued)EventEvent as shown inControl Panel LogSIA Report14 Cross,24hr Burg BM BurglaryAlarm CrossZone15 Cross,Cntrl,Dly BM BurglaryAlarm CrossZone16 Cross,Cntrl BM BurglaryAlarm CrossZone17 Cross,Unverified BG UnverifiedEvent BurglaryContact IDReport133 24 HrSafeEvent DescriptionAlarm, Burglary Zone Type withCross Zone Option selected134 Entry/Exit Alarm, Delay 1 or Delay 2 ZoneType with Cross Zone Optionselected.130 Burglary Alarm, Follower or Instant ZoneTypes with Cross Zone Optionselected.378 CrosszoneTrouble18 Alarm Exit Error EA Exit Alarm 374 Exit Error(zone)19 Alrm Recent Clse CR RecentClosing20 Alrm Recent Clse CR RecentClosing21 Auto On Extended CE ClosingExtend22 Battery Low YT SystemBattery Trouble23 Battery Missing YM SystemBattery Missing24 Rstrl Batt Low YR SystemBattery Restoral25 Rstrl Bat Missng YR SystemBattery RestoralA fault on one non-fire zone typewith the Cross Zone Optionselected. This is not an alarm event.Zone faulted at the end of ExitDelay.134 Entry/Exit Alarm event within 2 min. ofclosing.130 Burglary Alarm event within 2 min. ofclosing.464 Auto-armTime Extended302 LowSystem Battery311 BatteryMissing/Dead302 LowSystem Battery311 BatteryMissing/Dead26 Bypass,Fire,User FB Fire Bypass 571 Firebypass27 Bypass,Fire,RPSFB Fire Bypass28 Bypass,Ctrl,User BB BurglaryBypass29 Bypass,Ctrl, RPS BB BurglaryBypass30 Bypass,24hr,User BB BurglaryBypass571 Firebypass570Zone/Sensorbypass570Zone/Sensorbypass572 24-HrZone BypassZone TypesLinked to EventRPSEventGroup8- Burglary 311- E/E Delay 112- E/E Delay 213- Follower14- Instantany with CrossZone Option11- E/E Delay 112- E/E Delay 211- E/E Delay 112- E/E Delay 210- Keyswitch13- Follower14- Instant333333StatusReportAuto On Sked delayed one hour by10user. Report follows Open/Closerouting.Panel battery is low. 12 R SPanel battery is missing. Very low,shorted, or open batteries arereported as missing.12 R SBattery restoral from low battery. 12 R SBattery Restoral from missingbattery.Selective bypass by user, fire zonetypes.Selective bypass by RPS, fire zonetypes.Selective bypass by user,controlled zone types.Selective bypass by RPS, zonetypes.Selective bypass by user, 24-hournon-fire zone types.1- Fire2- Fire withAlarmVerification1- Fire2- Fire withAlarmVerification10 to 15- ZoneTypes10 to 15- ZoneTypes3 to 9- 24-hour,Non-Fire ZoneTypes12 R S151515Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!