<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 3. Control Panel Programming EN | 70PIN, User #• Address: See Table 28• Default:- User 1: 1, 2, 3, 4, 5, 6, 7- Users 2-32: 15, 15, 15, 15, 15, 15, 15• Selections: 0 to 9Enter a PIN for each user in the PIN parameter. The PIN length parameter determines the number of digits in thePINs.The default PIN length is 4 digits, which makes all User PINs four digits in length. For example, if a User PIN is7654321 and the PIN length is set to 4 digits, the User PIN changes to 7654.Do not use digits 10-15 when creating a User PIN. Entering these digits makes the PIN unusable andlocks the user out of the control panel.Authority Level, User #• Address: See Table 10• Default:- User 1: 1 (Authority Level 1)- Users 2 to 32: 0 (No Authority Level assigned)• Selections:- 0 = No Authority Level assigned (Disabled)- 1 = Authority Level 1 assigned- 2 = Authority Level 2 assigned- 3 = Authority Level 3 assigned- 4 = Authority Level 4 assignedThis parameter assigns an authority level to each user. The authority level assigns functions to the user’s PIN andRF keyfob. See “RF Keyfobs” in the <strong>DS7200V2</strong> Expert Programming Guide (P/N: 4998153891) for a description ofRF keyfobs and how to assign them to users.Authority levels are configured as shown below. See “Authority Level Configuration” in the <strong>DS7200V2</strong> ExpertProgramming Guide (P/N: 4998153891) to change the configuration of authority levels.• Authority Level 1 (Master): All options except for Option 5. A user with this authority level configurationcan arm and disarm the system, send reports, and perform all system functions except one-time disarm.• Authority Level 2 (Unlimited): All options except for Option 5 and 14. A user with this authority levelconfiguration can arm and disarm the system, send reports, and perform all system functions except one-timedisarm and change PINs.• Authority Level 3 (User): All options except for Options 5 and 8 to 15. A user with this authority levelconfiguration can arm and disarm the system, send reports, but can only perform a limited number of systemfunctions.• Authority Level 4 (One-Time): All options except 7 to 15. A user with this authority level configuration canarm and disarm the system (can only disarm the system once), send reports, but can only perform a limitednumber of system functions and cannot force-arm or bypass zones when arming the system.Bosch Security Systems, Inc. | 2/09 | 4998153893-03
<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 3. Control Panel Programming EN | 71Area Option, User #• Address: See Table 10• Default:- User 1:- DS7240V2: 15 (Areas 1 to 4)- DS7220V2: 3 (Areas 1 and 2)- Users 2 to 32: 0 (Not assigned to an area)• Selections: 0 to 15Enter This Data Digit to Select OptionsUser Area Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15Not Assigned to an Area •Assigned to Area 1 • • • • • • • •Assigned to Area 2 • • • • • • • •Assigned to Area 3 • • • • • • • •Assigned to Area 4 • • • • • • • •Assigning PINs to multiple areas allows users to view and operate multiple areas from a single keypad.RF ID for KeyfobYou must exit control panel programming in order to enter the RF ID code. Add RF ID codes after you completeyour programming session. See Adding RF ID Codes on page 41 for complete instructions.3.4.3 KeypadsWired Keypads 1 to 8 are fixed at Data Bus Addresses 1 to 8. See Keypad Addressing on page 14 for moreinformation. All keypads (and other Data Bus devices) are fully supervised. Supervision reports, such as missingand tamper reports, follow the System Status Report routing.Keypad # Options• Address:- Keypad 1: 0678- Keypad 2: 0680- Keypad 3: 0682- Keypad 4: 0684- Keypad 5: 0686- Keypad 6: 0688- Keypad 7: 0690- Keypad 8: 0692• Default: 7• Selections: 0 to 15Enter This Data Digit to Select OptionsKeypad Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15No Keypad Options •Beep Keypad on System Trouble • • • • • • • •Enable Exit Tone • • • • • • • •Enable Area Display (DS7446KP Keypad) • • • • • • • •Don’t Show Zone Status on Keypads • • • • • • • •Bosch Security Systems, Inc. | 2/09 | 4998153893-03