12.07.2015 Views

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 3. Control Panel Programming EN | 673.4 User Interface3.4.1 PIN Configuration/Installer PINA Personal Identification Number (PIN) is a unique number issued at the time of installation of each system.This PIN is required to operate the system (arm/disarm, test system, initiate functions, etc.). The PIN is not thesame as the account number.PIN Length• Address: 0379• Default: 4 (4 digits long)• Selections: 3 to 7 (3 digits min; 7 digits max)This parameter determines the number of digits in a PIN. All user PINs and the Installer PIN follow this length.If the PIN length is shortened after PINs are entered, duplicate PINs could be created (for example,PINs 1235 and 1238 would both become 123).User Tamper Options• Address: 0380• Default: 0• Selections: 0 to 3Enter This Data Digit to Select OptionsUser Tamper Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15No User Tamper Options •User Tamper {156} Reports Enabled • •User Tamper Activates Burg Alarm Output • •ReservedReservedA user tamper event is:- A user entering a PIN that is not in the system (the user must enter the invalid PIN the number of timesshown in User Tamper Retry Count on page 68).- A user entering a PIN that is in the system but does not have the authority for the desired function.• User Tamper Reports Enabled: If enabled, this option ties User Tamper {156} reports and user tamperactivated alarm outputs to the keypad’s area. If only the “User Tamper Reports Enabled” option is selectedand there is a user tamper event, the text keypad where the event occurs shows “Keypad locked!”• User Tamper Activates Burg Alarm Output: If the burglary alarm output (steady alarm output) is selectedand there is a user tamper event, the text keypad where the user tamper occurred shows “Keypad locked!”Other text keypads in the area show “Usr Tamper Alarm, Enter PIN to silence.” During the time the keypadis locked out, any key pressed produces an error tone (for text and LED keypads). Selecting the “User TamperActivates Burg Alarm Output” option specifically activates output functions 1|8, 1|9, 1|10, and 8|8. See Table34 on page 87 for descriptions of these output functions.Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!