12.07.2015 Views

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 4. Reference Materials EN | 115Table 40: Control Panel Events and Reporting Formats (continued)EventEvent as shown inControl Panel LogSIA Report149 Rstrl,Trbl,Invis HJ HoldupTrouble Restore150 Rstrl,Trbl,24-hr BJ BurglaryTrouble Restore151 Rstrl,Trbl,Dly BJ BurglaryTrouble Restore152 Rstrl,Trbl,Cntrl BJ BurglaryTrouble Restore153 User Code Area Set JY User CodeAdded154 User Code Change JV User CodeChanged155 User Code Delete JX User CodeDeleted156 User Code Tamper JA User CodeTamperContact IDReport375 PanicZone Trouble380 SensorTrouble380 SensorTrouble380 SensorTrouble461 WrongCode EntryEvent DescriptionRestoral from trouble condition onInvisible zone type.Restoral from trouble condition onBurglary zone type.Restoral from trouble condition onDelay zone types.Restoral from trouble condition onKeyswitch, Follower, and Instantzone types.Zone TypesLinked to EventRPSEventGroup7- Invisible Panic 88- Burglary15 - Door11- E/E Delay 112- E/E Delay 210- Keyswitch13- Follower14- InstantUser Code ‘added’ by assigning16 Rarea.User Code changed. 16 RUser Code deleted. 16 RInvalid User Codes entered atkeypad exceeded User TamperRetry Count. See page 68.88816 R157 User Level Set JZ User Level Set User Level set. 16 R158 Walk Test Start TS Test Start 607 Walk TestModeWalk Test started with Walk Testkey sequence ([#][4][4]).11159 Walk Test End TE Test End 607 Walk TestMode160 Siren Trouble YA Bell Fault 320 SounderRelay161 Siren Restoral YH Bell Restored 320 SounderRelay162 Grnd Fault IA EquipmentFailure Condition163 Grnd Fault, Rstl IR Equipment FailRestoral164 First Open OP OpeningReport165 Last Close CL ClosingReport166 AltCom Cond NC NetworkCondition167 AltComm Fail NT NetworkFailure168 AltComm Rstrl NR NetworkRestoral310 GroundFault310 GroundFault400Open/Close400Open/Close350CommunicationTrouble350CommunicationTrouble350CommunicationTroubleStatusReportWalk Test ended by user or timed11out.Trouble condition detected on PO12 R S2 configured as supervised sirenoutput.Trouble condition on supervised12 R Ssiren output cleared.Ground fault detected on panel’s12 R Ssensor loops, Option Bus, or Auxpower outputs.Ground fault condition cleared. 12 R SPanel is configured for multiplearea first to open, last to closefunction. See Arming Options 2 onpage 62. First area has opened.Panel is configured for multiplearea first to open, last to closefunction. See Arming Options 2 onpage 62. Last area has closed.Trouble detected on AlternateCommunication network.Network failure detected onAlternate Communication network.Network communication resumedon alternate communicationsnetwork.101012 R S12 R S12 R SBosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!