12.07.2015 Views

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 4. Reference Materials EN | 109Table 40: Control Panel Events and Reporting Formats (continued)EventEvent as shown inControl Panel Log31 Bypass,24hr,RPSSIA ReportBB BurglaryBypass32 Bypass,Forced Zn BB BurglaryBypass33 Bypass,Swinger BB BurglaryBypassContact IDReport572 24-HrZone Bypass570Zone/Sensorbypass575 SwingerShunt34 UnBypss,Fire, Usr FU Fire UnBypass 571 Firebypass35 UnBypss,Ctrl,Usr BU BurglaryUnbypass36 UnBypss,24hr,Usr BU BurglaryUnbypass37 Call for Service YX ServiceRequired38 Cancel Alarm BC BurglaryCancel570Zone/Sensorbypass572 24-HrZone Bypass616 ServiceRequestEvent DescriptionSelective bypass by RPS, 24-hournon-fire zone types.Zone force armed at force arming.Zone TypesLinked to Event3 to 9- 24-hour,Non-Fire ZoneTypes10 to 15- ZoneTypesRPSEventGroupZone Swinger Shunted. All zone types 15User cleared bypass (unbypass),Fire zone types.User cleared bypass (unbypass),controlled zone types.User cleared bypass (unbypass),24-hour zone types.This report sent automatically atCall for Service Interval. It does notindicate a trouble condition.406 Cancel User acknowledged active alarmbefore Bell Time expired, non-firezone types.39 Cancel Fire FC Fire Cancel 406 Cancel User acknowledged active alarmbefore Bell Time expired, fire zonetypes.40 CheckSum Fail YF ParameterChecksum Fail41 ChkSum Fail,DBus YF ParameterChecksum Fail42 Cls,All,+Dly,Skd CA AutomaticClosing43 Cls,All,+Dly,KS CS ClosingKeyswitch44 Cls,All,+Dly, RPS CQ RemoteClosing45 Cls,All,+Dly,Tel CQ RemoteClosing46 Cls,All,+Dly,Usr CL ClosingReport47 Cls,All,-Dly,RPS CQ RemoteClosing48 Cls,All,-Dly,Usr CL ClosingReport49 Cls,Prt,+Dly,Skd CA AutomaticClosing50 Cls,Prt,+Dly,KS CS ClosingKeyswitch303 RAMChecksum Bad330 SystemPeripheraltrouble403 AutomaticO/C409 KeyswitchO/C400Open/Close407 RemoteArm/Disarm401 O/C byUser400Open/Close401 O/C byUserChecksum on panel’s parametersfailed. Panel program should beverified.Checksum on Option Bus deviceparameters failed. Device shouldbe checked.System turned All On withEntry/Exit Delay by Sked.System turned All On withEntry/Exit Delay by Keyswitch.System turned All On withEntry/Exit Delay by RPS.System turned All On withEntry/Exit Delay by Telephone.System turned All On withEntry/Exit Delay by User.System turned All On with no delay(instant) by RPS.System turned All On with no delay(instant) by User.456 Partial Arm System armed Perimeter Only withEntry/Exit delay by Sked.442 KeyswitchArmed StaySystem armed Perimeter Only withEntry/Exit Delay by Keyswitch.1- Fire2- Fire withAlarmVerification10 to 15- ZoneTypes3 to 9- 24-hour,Non-Fire ZoneTypes1515151512 R87StatusReport12 R S12 R S10101010101010Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!