12.07.2015 Views

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 3. Control Panel Programming EN | 93Table 35: Output Mode Options (continued)Mode Mode Type OutputDescriptionType9 Latch,ReversedLogic NormalStateEventOutput turns off when the condition is active and remains off until [System Reset] ispressed.Output turns off when the event occurs and remains off until [System Reset] ispressed.10 Pulse,ReversedLogic NormalStateEventWhen the condition is active, the output pulses. When the condition is inactive, theoutput is on.When the event occurs, the output pulses. The output continues pulsing until [SystemReset] is pressed, then turns on.11 One-Shot,ReversedLogic Normal12 One-Shotwith Re-Trigger,ReversedLogic Normal13 One-Shotwith Reset,ReversedLogic NormalBase, Output ##StateEventStateEventStateEvent• Address: See Table 33 on page 85• Default: See Table 33 on page 85• Selections:- 0 = Disabled- 1 = 200 ms (on-board outputs only)- 2 = 1 second- 3 = 1 minute- 4 = 1 hourWhen the condition changes from inactive to active, the output turns off. The outputturns on at the end of the One-Shot time. While the output is off, any changes in thecondition are ignored.When the event occurs, the output turns off and remains off for the One-Shot time.While the output is off, a second event does not affect the output.When the condition changes from inactive to active, the output turns off and remainsoff for the One-Shot time. If the condition goes inactive and active again, the One-Shottime is restarted and the output remains off.When the event occurs, the output turns off and remains off for the One-Shot time. If anew event occurs, the One-Shot time is restarted and the output remains off.When the condition changes from inactive to active, the output turns off and remainsoff for the One-Shot time. If the condition goes inactive, the output is turned on early.When the event occurs, the output turns off and remains off for the One-Shot time.[System Reset] turns the output on early.Multiply the Base with the Multiplier to determine the output’s timing. See Table 36, on page 92, and Table 37, onpage 94.Multiplier, Output ##• Address: See Table 33• Default: See Table 33• Selections: 0,0 to 9,9Multiply the Base with the Multiplier to determine the output’s timing. See Table 36 and Table 37.Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!