12.07.2015 Views

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 4. Reference Materials EN | 130Keyswitch:Latching:Location:No Entry:Off Display:One-Time PIN:Options:PSTN:Parity:Parameter:Partial On:Perimeter Only:PIN:Press:RPS:Restoral Report:Sked:Swinger Shunt:Tamper:Trouble:Verified Alarm:Visible Zone:Zone:Zone Function:Zone Type:Two types: Momentary and Maintained. To operate a Momentary Keyswitch, insert the key, turn it andrelease it. The key returns to its starting position automatically. The key cannot be removed unless it is inthe starting position. A Maintained Keyswitch typically has two positions marked “Armed” and“Disarmed.” To operate, insert the key, turn to desired position and remove the key.The locking in of a circuit by means of a holding contact.A Location represents the following parameter assignments: Area, Zone Number and Device. A Locationtells the control panel in which Area a device is assigned and by which Zone Number it reports as.Turning the system on without Entry Delay.The display that appears when the system is turned off and no keys are pressed (normal display).A One-Time PIN can only be used once to turn the system off. This PIN is typically given to personnel whoneed temporary access to the premises, such as a baby-sitter or a service/maintenance crew.Options are a unique type of parameter that allows the installer to configure up to four features by enteringa Data Digit at a single Address.Public Switched Telephone Network. An assembly of communications facilities and central officeequipment operated jointly by authorized common carriers that provides the general public with the abilityto establish communications channels via discrete dialing codes.A method of checking the accuracy of transmitted data by adding an extra bit to the number whennecessary to make the number odd or even.Each program parameter sets a specific value or chooses an option.A user-defined subset of the zones that arm. Partial On with No Entry (Instant) is an option.An installer-defined subset of the zones that arm. Perimeter Only with No Entry (Instant) is an option.Personal Identification Number. A unique number issued at the time of installation of each system. This PINis required to operate the system (arm/disarm, test system, initiate functions, etc.). The PIN is not the sameas the account number.These are used interchangeably instructing you to push down and then release a key.Remote Programming Software is a Windows • -based account management and control panelprogramming utility designed to remotely set up and program specific control panels.A signal transmitted upon the removal of a trouble or alarm condition from a zone.A scheduling parameter that allows a selected event to happen at a specific time.A programmable feature that determines the number of alarms or troubles the zone can transmit. If thenumber is exceeded, the zone is bypassed for the remainder of the arming period.Tamper conditions can be generated several different ways. A tamper-wired zone can report tamperbecause the zone is open or shorted. An RF transmitter can report a zone tamper because its case wastampered. A zone can be configured as a tamper zone. An off-normal tamper zone is a tamper condition.Different hardware devices can report tamper, including keypads, zone expanders, and RF receivers.A service condition that needs to be corrected, such as a broken wire.When the area is armed, the first alarm (an unverified alarm) sends its normal alarm report. The VerifiedAlarm timer begins. If a second alarm occurs while the Verified Alarm Timer is running, the second alarmsends its normal alarm report and then sends a Verified Alarm report. If a second alarm occurs after theVerified Alarm Timer has expired, the second alarm starts the Verified Alarm Timer again and only sends itsnormal alarm report. A third alarm would have to occur when the Verified Alarm Timer is running in order tosend the Verified Alarm report.A zone that displays at keypads during alarm or trouble conditions.The control panel reports changing conditions on the sensor loops as Zone events. For example, when thecondition on On-board Sensor Loop 1 changes from Normal (supervised EOL resistor in place) toShorted, the control panel can be programmed to create an alarm event for Zone 1. That alarm eventappears in keypad displays as “Alarm, Zn 1.” If programmed for reporting, the control panel would send an“Alarm, Zn 1” report to the ARC receiver in the programmed reporting format.Use to construct “personality types” for zones used in the control panel. Each unique Zone FunctionConfiguration determines responses to specific conditions occurring on the zones.Describes what the zone does. For example, Fire zone, Burglar zone, 24-hour zone, etc.Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!