<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 4. Reference Materials EN | 112Table 40: Control Panel Events and Reporting Formats (continued)EventEvent as shown inControl Panel LogSIA Report87 Missing,Alarm UZ UntypedMissing Alarm88 Missing,Trouble UY UntypedMissing Trouble89 Open,Skd OA AutomaticOpening90 Open,RPS OQ RemoteOpening91 Open,Usr OP OpeningReport92 Open,KS OS OpeningKeyswitch93 Open,Skd,Alarm OR Disarm fromAlarm94 Open,RPS,Alarm OR Disarm fromAlarm95 Open,Usr,Alarm OR Disarm fromAlarm96 Open,KS,Alarm OR Disarm fromAlarm97 Reserved98 Params Changed YG ParameterChanged99 Phone Line Fail LT Phone LineTrouble100 Phone Line Rstl LR Phone LineRestoral101 Bad Call to RPS RA RemoteProgrammer CallFailed102 RPS Access Fail RU RemoteProgram Fail103 RPS Access OK RS Valid RemoteAccessContact IDReport150 GeneralAlarm382 Loss ofsupervision –RPM403 AutomaticO/C400Open/Close401 O/C byUser409 KeyswitchO/C403 AutomaticO/C400Open/Close401 O/C byUser409 KeyswitchO/C306 PanelProgrammingChanged351 Telco 1fault351 Telco 1fault413Unsuccessfulaccess413Unsuccessfulaccess412SuccessfulDownload/Access104 Re-Boot,Panel RR Power Up 305 Systemreset105 Re-Boot,Dbus RR Power Up 339 Exp.Module Reset106 Output Reset,Usr RO Relay Open 320Sounder/Relay107 Output Reset,Skd RO Relay Open 320Sounder/RelayEvent DescriptionZone assigned to zone expander(wired or RF) not responding topanel’s status poll while the area isarmed.Zone assigned to zone expander(wired or RF) not responding topanel’s status poll while the area isdisarmed.Zone TypesLinked to Event6- 24-hr Burg10-15 ZoneTypes3-8, 10-15 ZoneTypesRPSEventGroup3Opening by Sked. 10Opening by RPS.Opening by user, ID reported. 10Opening by Keyswitch. 10Opening after Alarm event by Sked. 10Opening after Alarm event by RPS.Opening after Alarm event, IDreported.Opening after Alarm event byKeyswitch.Panel Parameters Changed. 12 RPhone line voltage less than 3 voltsfor 40 sec.After Phone Line Fail event, phoneline voltage detected at greaterthan 3 volts for 40 sec.Panel attempted call to RPS, butwas unsuccessful.RPS attempted to connect to panelbut was not successful.RPS successfully connected toand disconnected from panel.61010StatusReport12 R S12 R S12 RNormal start up or reset afterprogramming.R SUnexpected reset (reboot) from12 R SData Bus device.Output Reset by User 16 ROutput Reset by Sked 16 RRRBosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!