<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 3. Control Panel Programming EN | 65Area # Opening {89-96}/Closing {42-67} Reporting Options• Address:- Area 1: 0296- Area 2: 0318- Area 3 (DS7240V2 only): 0340- Area 4 (DS7240V2 only): 0362• Default: 1• Selections: 0, 1, 3, 5, 7, 9, 11, 13, 15Enter This Data Digit to Select OptionsArea # Open/Close Reporting Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15No Open or Close Reports for Area # •Open/Close Reports (for All On) for Area # Enabled • • • • • • • •Restrict Open/Close Reports; Open after Alarm, Closeon Force ArmOpen/Close Reports for Perimeter Only (and Partial On)Mode – Must also select Open/Close Reports (for AllOn)• • • •• • • •1 Second Bell Test on Closing Rpt Acknowledgement • • • •• Open/Close Reports for Area # Enabled: If enabled, this option configures Opening/Closing reports foreach area. This also includes the report for the Extend Auto Closing {21} event. Opening {89 to 96} andClosing {42 to 67} reports must be enabled at the system level. Opening and Closing reports are also enabledby authority level. Reporting must also be enabled at the system level (see Global Reporting Options on page57).• Restrict Open/Close Reports; Open From Alarm, Close on Force Arm: If this option is enabled, thecontrol panel only sends opening reports when the user disarms the system after an alarm and when BellTime has expired. The control panel only sends closing reports when a zone is force-armed. Force arming isset by authority level and by zone function configuration.Enabling the “Restrict Open/Close Reports” option overrides the “First Area to Open/Last Area toClose Reporting” option. See Arming Options 2 on page 62 for more information on the “RestrictOpen/Close Reports” option.• Open/Close Reports for Perimeter Only Mode: If this option is enabled, the control panel sends closingreports when users arm the system Perimeter Only. If any zones are bypassed, bypass reports are also sent.The control panel sends opening reports when users disarm the system. Perimeter Only arming is set byauthority level and by Zone Function configuration.• 1 Second Bell Test on Closing Ack: If this option is enabled, outputs assigned to Alarm Output Functions1|8, 1|9, 1|10, and 8|8 activate for one second. See Function, Output ## on page 87 for output functiondescriptions.Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!