12.07.2015 Views

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 2. System Installation and Setup EN | 172.2.6 Silencing an Alarm with a KeyswitchMomentary Keyswitch: To silence alarms (stopAlarm output), operate the keyswitch. If the area isarmed, operating the keyswitch to silence the alarmalso disarms the area. If the area is disarmed, operatinga momentary keyswitch to silence the alarm does notarm the area.Maintained Keyswitch: If the area is armed, turn thekeyswitch to the disarmed position. The control paneldisarms the area and silences the alarm. If the area isdisarmed, turn the keyswitch to the armed position (thecontrol panel does not arm) and then return to thedisarmed position.2.2.7 Exit Terminator ButtonWhen the Keyswitch Zone Function Options 1parameter (see “Options 1, Zone Function ##” in the<strong>DS7200V2</strong> Expert Programming Guide(P/N: 4998153891)) is set to 15, the input functions asan exit terminator button. This zone function activatesin the same manner as the momentary keyswitch.When Exit Delay is active, operating the exitterminator button terminates Exit Delay andimmediately arms the control panel. If Chime Mode isenabled and Exit Delay is not active, pressing the exitterminator button activates the chime tone and thebutton functions as a doorbell.2.3 On-board Sensor Loop Setup2.3.1 OverviewThe control panel provides eight on-board sensor loops(L-1 to L-8). Each sensor loop operates independentlyand does not interfere with the operation of the others.The default End-of-Line (EOL) resistor selection for theon-board sensor loops is the single alarm contacttamper-wired configuration.See “Global Zone Configuration” in the <strong>DS7200V2</strong>Expert Programming Guide (P/N: 4998153891) tomodify the on-board sensor loop EOL resistorconfiguration.2.3.2 Tamper-Wired Zone ConfigurationThe on-board sensor loops can be used as tamperwiredzones to report tamper conditions when the zonehas become open or shorted.See Figure 15 to wire a sensor loop as a tamper-wiredzone.Figure 15: Tamper-Wired Zone Configuration12341- Tamper contact2- Alarm contact3- Multiple alarm contact configuration only(5 contacts max)4- 2.2 kΩ EOL resistor5- 2.2 kΩ alarm resistor5Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!