<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 3. Control Panel Programming EN | 89Table 34: Output Function Types (continued)Digit 1 Digit 2 Function Type Description1 7 Silent Alarm Activated by alarm on non-fire zones programmed for No Alarm Output.Follows Bell Time for Steady and Pulse modes. PIN stops. The followingconditions activate Silent Alarm:- ABC Key programmed for Fire or Emergency and no Alarm Output- RF Keyfob programmed for Fire or Emergency and no Alarm Output- A zone programmed for Fire or Fire with Verify and no Alarm Output- Any zone not programmed for Invisible Panic that is programmed for noAlarm Output- Any armed zone programmed as a controlled type that goes fromSupervised to Missing and programmed for no Alarm Output- Any armed keyswitch programmed for no Alarm Output that goes fromSupervised to Missing or Short to Missing- Any zone programmed for Swinger Count and Swinger Count for AlarmOutput that reaches its programmed value1 8 Alarm – All On, Perimeter Only,and Partial On Arming, Non-fire24 hour alarms1 9 Alarm – Perimeter Only andPartial On Arming Modes, Nonfire24 hour alarms1 10 Alarm –Controlled zones, 24-hrzones (Fire and Non-Fire)Activated by alarm on zone when All On, Perimeter Only, and Partial OnArmed, or by alarm on Non-fire 24 hour zone, and by user/installer ‘BellTest’. Follows Bell Time for Steady and Pulse modes. PIN resets. Followsprogramming for ‘Alarm’ output types.Activated by alarm on zone when Perimeter Only, and Partial On Armed,or by alarm on Non-fire 24 hour zone, and by user/installer ‘Bell Test’.Follows bell time for Steady and Pulse modes. PIN resets.Follows programming ‘Alarm’ output types.Activated by alarm on zone when All On, Perimeter Only, and Partial OnArmed, or by alarm on Fire and Non-fire 24 hour zone, and byuser/installer ‘Bell Test’. Follows bell time for Steady and Pulse modes.Pulses in Temporal Code 3 format for Fire alarms only. PIN resets.Off-board outputs cannot provide output in Temporal Code 3 format(only on-board outputs). Off-board outputs provide a steady output.Follows programming for ‘Alarm’ output types. Temporal Code 3 forFire alarms only.1 11 Fire Alarm Activated by alarm on Fire zone, and by user/installer ‘Bell Test’. FollowsBell Time. Pulses in Temporal Code 3 format. Mode and Time parametersdo not apply. PIN resets. Off-board outputs cannot provide output inTemporal Code 3 format (only on-board outputs). Off-board outputsprovide a steady output. Follows programming for ‘Alarm’ outputtypes.1 12 Fire Alarm, Latching Activated by alarm on Fire zone, and by user/installer ‘Bell Test’. Does notpulse in Temporal Code 3 format. Mode and Time parameters do notapply. [#][4][7] resets. Follows programming for ‘Alarm’ output types.1 13 Fire Verification/Reset Normally on. Turns off on activation to reset smoke detectors. Verificationfor Fire Verification Zone Function type and [System Reset] activateoutput for approximately 15 sec. Mode and Time parameters do notapply. Used for 4-wire smoke detectors.1 14 System Trouble Activates on any System Trouble. Resets when all system troubles areclear.1 15 [O] Key (Trapezoid Key on RFKey Fob)Activates when Trapezoid Key on RF Keyfob is pressed. [System Reset]resets. Pressing O (trapezoid) key again also resets output when OutputMode is set to Toggle. This output type is event-driven. See Mode(Steady, Pulse, One Shot), Output ## on page 92 for more information.Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!