12.07.2015 Views

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 3. Control Panel Programming EN | 70PIN, User #• Address: See Table 28• Default:- User 1: 1, 2, 3, 4, 5, 6, 7- Users 2-32: 15, 15, 15, 15, 15, 15, 15• Selections: 0 to 9Enter a PIN for each user in the PIN parameter. The PIN length parameter determines the number of digits in thePINs.The default PIN length is 4 digits, which makes all User PINs four digits in length. For example, if a User PIN is7654321 and the PIN length is set to 4 digits, the User PIN changes to 7654.Do not use digits 10-15 when creating a User PIN. Entering these digits makes the PIN unusable andlocks the user out of the control panel.Authority Level, User #• Address: See Table 10• Default:- User 1: 1 (Authority Level 1)- Users 2 to 32: 0 (No Authority Level assigned)• Selections:- 0 = No Authority Level assigned (Disabled)- 1 = Authority Level 1 assigned- 2 = Authority Level 2 assigned- 3 = Authority Level 3 assigned- 4 = Authority Level 4 assignedThis parameter assigns an authority level to each user. The authority level assigns functions to the user’s PIN andRF keyfob. See “RF Keyfobs” in the <strong>DS7200V2</strong> Expert Programming Guide (P/N: 4998153891) for a description ofRF keyfobs and how to assign them to users.Authority levels are configured as shown below. See “Authority Level Configuration” in the <strong>DS7200V2</strong> ExpertProgramming Guide (P/N: 4998153891) to change the configuration of authority levels.• Authority Level 1 (Master): All options except for Option 5. A user with this authority level configurationcan arm and disarm the system, send reports, and perform all system functions except one-time disarm.• Authority Level 2 (Unlimited): All options except for Option 5 and 14. A user with this authority levelconfiguration can arm and disarm the system, send reports, and perform all system functions except one-timedisarm and change PINs.• Authority Level 3 (User): All options except for Options 5 and 8 to 15. A user with this authority levelconfiguration can arm and disarm the system, send reports, but can only perform a limited number of systemfunctions.• Authority Level 4 (One-Time): All options except 7 to 15. A user with this authority level configuration canarm and disarm the system (can only disarm the system once), send reports, but can only perform a limitednumber of system functions and cannot force-arm or bypass zones when arming the system.Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!