<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 4. Reference Materials EN | 111Table 40: Control Panel Events and Reporting Formats (continued)EventEvent as shown inControl Panel LogSIA Report74* Duress HA Hold UpAlarmContact IDReportEvent Description121 Duress User entered Duress PIN orpressed Panic key sequence or [Q]button** on RF Keyfob. The Duressreport is sent in addition to anyother report that the user’s actionwould generate.Zone TypesLinked to Event75 Fire,Alarm FA Fire Alarm 110 Fire Alarm event on fire zone type. 1- Fire2- Fire withAlarmVerification76 Fire,Cross FM Fire AlarmCross Zone77 Fire,Un-verified FG UnverifiedEvent-Fire78 Fire, Missing FY Missing FireTrouble79 Fire,Alrm,Rstl FH Fire AlarmRestore110 Fire Verified alarm event on fire zonetype with Cross Zone Option. See“Zone Response Options” in the<strong>DS7200V2</strong> Expert ProgrammingGuide (P/N: 4998153891).378 CrosszoneTrouble373 FireTrouble80 Fire,Trouble FT Fire Trouble 373 FireTrouble81 Fire,Trbl,Rstl FJ Fire TroubleRestoreUnverified alarm event on fire zonetype with Cross Zone Option. Orunverified event on Fire Verify zonetype.Fire zone type assigned to zoneexpander (wired or RF) notresponding to panel’s status poll.110 Fire Restoral from alarm, Fire zonetypes.373 FireTrouble82 Instl Mode,Start LB Local Program 466 ServiceOn Premises83 Instl Mode,End LX LocalProgrammingEnded466 ServiceOff Premises84 Log Overflow JO Log Overflow 624 Event LogOverflowFault (Trouble) condition on Firezone types.Restoral from Trouble, Fire zonetypes.RPSEventGroup121- Fire 21- Fire2- Fire withAlarmVerification1- Fire2- Fire withAlarmVerification1- Fire2- Fire withAlarmVerification1- Fire2- Fire withAlarmVerification1- Fire2- Fire withAlarmVerificationInstaller PIN entered. Installer mode11 Raccessed.Installer mode exited. 11 RPanel log overflow condition.Oldest events being overwritten.85 Log Threshold JL Log Threshold 623 Event Log Panel log reached threshold. See“Log Supervision Configuration” inthe <strong>DS7200V2</strong> ExpertProgramming Guide.86 AltCom Low Signl XL Low ReceivedSignal Strength350CommunicationTroubleLow Signal Strength detected onAlternate Communication device.5575712 R12 R* This event reports a user number + 200 when sent using SIA and Contact reporting formats.** See the <strong>DS7200V2</strong> Expert Programming Guide (P/N: 4998153891) for information on [Q] button programming.StatusReport12 R SBosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!