<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 4. Reference Materials EN | 114Table 40: Control Panel Events and Reporting Formats (continued)EventEvent as shown inControl Panel LogSIA Report130 Dbus Troubl,Rstl ER ExpansionRestoral131 Dbus OverCurrent YI OvercurrentTrouble132 Dbus OvrCur,Rstl YJ OvercurrentRestoreContact IDReport330 SystemPeripheralTrouble330 SystemPeripheralTrouble330 SystemPeripheralTrouble133 Sensor Mon Trbl NA No Activity 391 SensorWatch trouble134 Sensor Mon Rstl NS ActivityRestored391 SensorWatch troubleEvent DescriptionData Bus Device Fault (Trouble)condition cleared.Over current condition detected onData Bus device.Over current condition on Data Busdevice restored.Sensor fault (trouble) detected.Reports follow zone trouble routing.Sensor trouble condition restored.Reports follow zone trouble routing.135 Sensor Reset Local Event Only User entered System Reset keysequence ([#][4][7]).136 System Inactive CD ClosingDelinquent137 Test, OK RP AutomaticTest138 Test,Off-Normal RY Test OffNormal139 Trbl,Tamper TT TamperTrouble140 Trbl,Emergency QT EmergencyTrouble602 PeriodTest Report608 PeriodTest Report,System TroublePresent380 SensorTrouble380 SensorTrouble141 Trbl,Panic PT Panic Trouble 375 PanicZone Trouble142 Trbl,Invisible HT HoldupTrouble143 Trbl,24-hr Burg BT BurglaryTrouble144 Trbl,Cntrl,Dly BT BurglaryTrouble145 Trbl,Cntrl BT BurglaryTrouble146 Rstrl,Trbl,Tmpr TJ TamperTrouble Restore147 Rstrl,Trbl,Emerg QJ EmergencyTrouble Restore148 Rstrl,Trbl,Panic PJ Panic TroubleRestore375 PanicZone Trouble380 SensorTrouble380 SensorTrouble380 SensorTrouble380 SensorTrouble380 SensorTrouble375 PanicZone TroubleZone TypesLinked to Event11-15 ZoneTypes11-15 ZoneTypesRPSEventGroupStatusReport12 R S12 R S12 R SSystem was not armed in InactiveInterval.. System Reset keysequence ([#][4][7]) or armingresets this trouble.12 RNo system troubles at automatic13test report time.System trouble present at test time. 13Trouble condition on Tamper or anytamper-wired zones.Trouble condition on Emergencyzone type.Trouble condition on Panic zonetype.Trouble condition on Invisible zonetype.Trouble condition on Burglary zonetype.Trouble condition on Delay zonetypes.Trouble condition on Keyswitch,Follower, and Instant zone types.Restoral from Tamper troublecondition.Restoral from trouble condition onEmergency zone type.Restoral from trouble condition onPanic zone type.66124-Tamper6or any zone5- Emergency 66- Visible Panic 67-Invisible Panic 66- Burglary615 – Door11- E/E Delay 1 612- E/E Delay 26- Keyswitch 613- Follower14- Instant4-Tamper8or any zone5- Emergency 86- Visible Panic 8Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!