12.07.2015 Views

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 4. Reference Materials EN | 113Table 40: Control Panel Events and Reporting Formats (continued)EventEvent as shown inControl Panel LogSIA ReportContact IDReport108 Output Reset,RPS RO Relay Open 320Sounder/Relay109 Output Set,Usr RC Relay Close 320Sounder/Relay110 Output Set,Skd RC Relay Close 320Sounder/Relay111 Output Set,RPS RC Relay Close 320Sounder/Relay112 Rstrl,Tamper TR TamperRestoral113 Rstrl,Emergency QR EmergencyRestoral114 Rstrl,Panic PR PanicRestoral115 Rstrl,Invisible HR HoldupRestoral116 Rstrl,24-hr Burg BR BurglaryRestoral117 Rstrl,Cntrl,Dly BR BurglaryRestoral118 Rstrl,Cntrl BR BurglaryRestoral119 Rcvr Jam XQ RFInterference120 Rcvr Jam Rstl XH RFInterferenceRestoral121 RF Battery Low XT TransmitterBattery Trouble122 RF Battery Rstl XR TransmitterBattery Restoral123 RF Tamper Trbl TT TamperTrouble124 RF Tamper Rstl TR TamperTrouble Restore125 Dbus Missing EM ExpansionDevice Missing126 Dbus Missng,Rstl EN ExpansionMissing Restore127 Dbus Tamper ES ExpansionDevice Tamper128 Dbus Tamper,Rstl EJ ExpansionTamper Restore129 Dbus Trouble ET ExpansionTroubleEvent DescriptionOutput Reset by RPSZone TypesLinked to EventRPSEventGroupOutput Set by User 16 ROutput Set by Sked 16 ROutput Set by RPS137 Tamper Restoral from alarm, Tamper zonetype.101 PersonalEmergencyRestoral from alarm, Emergencyzone type.120 Panic Restoral from alarm, Panic zonetype.120 Panic Restoral from alarm, Invisible zonetype.133 24hr(Safe)Restoral from alarm, 24-hourburglary zone types.134 Entry/Exit Restoral from alarm, Delay 1 or 2zone types.130 Burglary Restoral from alarm, Keyswitch,Follower, or Instant zone types.344 RFReceiver JamDetect344 RFReceiver JamDetect Restoral384 RF LowBattery384 RF LowBattery383 SensorTamper383 SensorTamper333 Exp.Module Failure333 Exp.Module Failure341 Exp.Module Tamper341 Exp.Module Tamper330 SystemPeripheralTroubleJammed condition detected onpremises RF receiver.Jammed condition detected onpremises RF receiver cleared.4- Tamper 85- Emergency 86- Visible Panic 87-Invisible Panic 86- Burglary15 – Door11- E/E Delay 112- E/E Delay 26- Keyswitch13- Follower14- Instant888StatusReportRR9 R S9 R SLow Battery detected on premisesRF transmitter.Any zone type 9Low Battery condition detected on Any zone type 9premises RF transmitter cleared.Premises RF Transmitter Tamper Any zone type 9Fault (Trouble).Premises RF Transmitter Tamper Any zone type 9Restoral.Data Bus device not responding to12 R Spolling.Data Bus device declared as12 R Smissing now responding to polling.Tamper open on Data Bus Device12 R STamper.Data Bus Device Tamper Restoral. 12 R SFault (Trouble) detected on DataBus Device.12 R SBosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!