<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 3. Control Panel Programming EN | 90Table 34: Output Function Types (continued)Digit 1 Digit 2 Function Type Description2 0 [P] Key (Rising Sun Key on RFFob)Activates when Rising Sun Key on RF Keyfob is pressed. [System Reset]resets. Pressing P (sun) key again also resets output when Output Modeis set to Toggle. This output type is event-driven. See Mode (Steady,Pulse, One Shot), Output ## on page 92 for more information.2 1 ‘Panic’ on RF Fob Activates when Arm Key (locked icon) and Disarm Key (unlocked icon) onRF Keyfob are pressed at the same time, or when the [Q] button ispressed and it is set to Duress. See the <strong>DS7200V2</strong> Expert ProgrammingGuide (P/N: 4998153891) for [Q] button information. [#][4][7] resets.2 2 ‘Panic’ on RF Fob, Bell Time,PIN resets2 3 [A] Key2 4 [B] Key2 5 [C] Key2 6 3 Unsuccessful DialingAttemptsActivates when Arm Key (locked icon) and Disarm Key (unlocked icon) onRF Keyfob are pressed at the same time, or when the [Q] button ispressed and it is set to Duress. Steady and Pulse modes follow bell time.PIN resets.Activates when appropriate keys are pressed. [System Reset] resets if noalarm response is assigned. These output types are event-driven. SeeMode (Steady, Pulse, One Shot), Output ## on page 92 for moreinformation.Activates after 3 unsuccessful dialing attempts. Resets with firstsuccessful call or [System Reset].2 7 Communication Fail Event Activates after Communication Fail Event. Resets with any successfulcommunication or [System Reset].2 8 Panel Off Hook Activates when the control panel takes the phone line off hook for adialing attempt. Resets when the control panel finishes with the phoneline and goes on hook.2 9 Ring Detect Activates when the control panel detects a ring on the phone line. Resetswhen ringing stops.2 10 Voice Request For use with an optional Voice Verification Module. The output activatesfor 2 sec when the control panel receives an acknowledgement of analarm report from a zone with the Voice Verification option enabled. Modeand Time parameters do not apply.2 11 Follow Keypad Sounder Available for on-board outputs only. Output follows keypad sounder Modeand Time parameters do not apply.2 12 Chime Activates per Chime configuration. Follows keypad sounder per ChimeTone configuration.2 13 Ready to Arm (No zonesfaulted)Output is activated (on) when: (1) control panel is disarmed & no zonesare faulted (2) control panel is armed & no zones are faulted (3) controlpanel is armed and any zone is faulted. Output is deactivated (off) whencontrol panel is disarmed & any zone is faulted. Output is deactivatedeven if the zone became faulted when control panel was armed.2 14 Exit Error/Bad Set Activates if zone is faulted at the end of Exit Delay or if a Bad Setcondition occurs. Resets when the system is disarmed.2 15 AC 60 Hz Activates on 60 Hz. Deactivates on 50 Hz.3 0 Ground Start Activates for approximately 0.5 sec at the start of any dialing attempt. Useto bring up dial tone in ground start phone systems.3 1 Follow Zone Function 1to3 15 Follow Zone Function 15These 15 output functions activate for any fault on any zone assigned tothe specified Zone Function.4 0 Change Outputs Activated/deactivated by Change Outputs function ([#][5][4]).4 1 Alarm Zone Function 1to4 15 Alarm Zone Function 15These 15 output functions activate for alarms on any zone assigned to thespecified Zone Function and the area(s) the output is assigned to. Theyreset when none of the zones assigned to the specified Zone Functionare in alarm.5 0 Change Outputs Activated/deactivated by Change Outputs function ([#][5][4]).Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!