12.07.2015 Views

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 4. Reference Materials EN | 1184.2 TroubleshootingUse this section to troubleshoot problems with the control panel.Below are various problems that may occur, followed by explanations of the problems (cause) and solutions.Arming IssuesProblem Cause SolutionI enter a valid PIN to arm an Area,but the Area does not arm.• No zones are programmed for thatArea.• Add a minimum of one zone to eachArea.• User does not have the appropriateAuthority Level to arm system.• Must press On or Perimeter Only keys.• Make sure users who should be able toarm/disarm the system have theappropriate Authority Level.I cannot tell if my system is armedfor Perimeter Only or Partial Onfrom a DS7445i/DS7445V2 LEDKeypad.I armed my system All On, but itkeeps changing to Perimeter Only.I am using an exit terminatorswitch. When I try to arm, thekeypad does not show any delay.The keypad turns the Perimeter Only LEDon for both of these arming options, butcannot distinguish between the two.The “All On-No Exit” arming option isenabled. When the panel was armed,nobody faulted an Entry/Exit Delay zone,therefore the panel did not arm thoseinternal zones.Exit delay set to zero.There is no solution. The user who arms thesystem must know which keys were pressed([Perimeter Only] or [#][2] for PerimeterOnly; [#][3] for Partial On).See Arming Options 1on page 61 (Address0258) to disable this option.Do not use exit delay set to zero with exitterminator. Set for at least ten sec.Zone IssuesProblem Cause SolutionI have a trouble on a keyswitchzone and it does not clear. Thezone is restored to its normalcondition.There is no output after alarming azone.Swinger Shunt on a keyswitch might beenabled on this Zone Function. The zonedoes not restore until the Swinger Shuntcondition restores.Incorrect programming.Arm and disarm the system to clear thecurrent trouble. To prevent this in the future,check the Keyswitch Zone Functionprogramming and make sure Swinger Shuntis disabled. See the <strong>DS7200V2</strong> ExpertProgramming Guide (P/N: 4998153891) forcomplete zone function programminginstructions.Review the following sections to see if theoutput is correctly programmed:• See “Options 2, Zone Function ##” inthe <strong>DS7200V2</strong> Expert ProgrammingGuide (P/N: 4998153891).• See Output Parameters on page 85.Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!