<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 3. Control Panel Programming EN | 56Phone Line Fault Response Options• Address: 0220• Default: 0• Selections: 0, 1, 3, 5, 7Enter This Data Digit to Select OptionsPhone Line Fault Response Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15No Phone Line Supervision •Enable Supervision (System Trouble at Keypad) • • • •Burg Alarm & Strobe Functions, All On/PerimeterOnly• •Burg Alarm & Strobe Functions, Off • •ReservedThe control panel monitors the phone line for voltage only. If the voltage drops low enough (between 1 and 3 V)for 40 sec, it declares a phone line fault. If the phone line voltage remains above 3 volts for at least 40 sec, itdeclares the phone line restored. See the “Phone Line Fault Requires Reset” option in Phone Line Options on page54.When enabled, the Phone Line Fault event appears at all keypads for all areas. The control panel sends a PhoneLine Restore {100} report when a phone line fault event restores.If the phone line fails (as described above), but restores before a Comm Fail event:1. System detects phone line fail and puts Event {99} in the log.2. System starts dialing attempts if programmed for Phone Fail report.3. Phone line restores before Comm fail event.4. System sends phone line fail and phone line restore reports.If the phone line fails (as described above), but restores after a Comm Fail event:1. System detects phone line fail and puts report in the event in the log.2. System starts dialing attempts if programmed for Phone Fail report.3. Dialing attempts end with Comm fail event, phone fail report is flushed.4. System detects phone line is restored and puts restoral report in buffer.5. System starts dialing attempts and sends phone fail restoral and Comm restoral reports.If an alternate communication path is enabled, the control panel can send a Phone Line Fail {99} report via thealternate communication path when a phone line fault event occurs.• No Phone Line Supervision: If this option is enabled, the control panel does not monitor the phone linevoltage. Phone Line Fault events do not appear at keypads. The other Phone Line Fault Response options arealso disabled if No Phone Line Supervision is selected.• Enable Supervision (System Trouble at Keypad): If this option is enabled, the keypad displays a phoneline trouble message if a phone line fault occurs as described above. To enable the keypad to sound a troubletone on system troubles, see Keypad # Options on page 71 for details.• Burg Alarm & Strobe Functions, All On or Perimeter Only: If this option is enabled, the system’s burglaryalarm and strobe function as configured when the system is armed All On or Perimeter Only if a phone linefault occurs as described above. See Output Parameters on page 85 for burglary alarm/strobe outputconfiguration.• Burg Alarm & Strobe Functions, Off: If this option is enabled, the system’s burglary alarm and strobefunction as configured when the system is off (not armed) if a phone line fault occurs as described above. SeeOutput Parameters on page 85 for burglary alarm/strobe output configuration.Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!