<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 3. Control Panel Programming EN | 573.2.4 Global Reporting OptionsThese parameters configure the reporting for all areas, all zones, and all users.Global Reporting Options• Address: 0221• Default: 1• Selections: 0, 1, 3, 5, 7, 9, 11, 13, 15Enter This Data Digit to Select OptionsGlobal Reporting Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15Local Only •Enable Reporting • • • • • • • •Extend Handshake • • • •Delay Alarm Output • • • •Burg Alarm after Two Failed Attempts • • • •• Local Only: The control panel sends no reports.• Enable Reporting: If this option is enabled, the control panel sends reports as programmed provided that atleast one phone number (or IP address) has been programmed for at least one Routing Destination (see PhoneNumber 1 (2) for Destination 1 (2) on page 49). Reporting options can be enabled and disabled in otherparameters. See Open/Close Reporting Options on page 63, and Area # Opening {89-96}/Closing {42-67} ReportingOptions on page 65 for more information.• Extend Handshake: If this option is enabled, the control panel finishes dialing the ARC receiver and waitsfor a ‘handshake’ tone from the receiver. The handshake is the first thing the receiver sends after answeringthe phone. Typically each reporting format the receiver supports has its own handshake tone. If a receiversupports several formats, it sounds the handshake tones one at time. Choosing this option extends the time thecontrol panel waits for a handshake from the ARC receiver from 45 to 60 sec.Do not change the Extend Handshake option unless advised by Bosch Technical Service.• Delay Alarm Output: If this option is enabled, the control panel delays burglary alarm output untilcommunication to the ARC receiver is complete or there are two failed dialing attempts. The delayed alarmoutput functions are 1|8, 1|9, and 1|10 (see Table 34 for descriptions of output function types). Bell Time is notdelayed, and begins at the alarm event. If Bell Time is set at 3 min. or less, alarm output delayed by thisoption may be very short (less than 1 minute), or the alarm output may not activate at all. See OutputParameters on page 85 for a complete description of output functions. The keypad sounder is not delayed bythis option.In order to use the Delay Alarm Output option, the Alarm Event Abort option must be disabled. See“Options 1, Zone Function ##” in the <strong>DS7200V2</strong> Expert Programming Guide (P/N: 4998153891).Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!