12.07.2015 Views

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

DS7200V2-EXP - Simon Technologies

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>DS7200V2</strong>-<strong>EXP</strong> | Installation Guide | 3. Control Panel Programming EN | 953.7 Sked ParametersSkeds are programmable events that occur at a specified time of day and day of the week.Users can extend Auto On, Auto Perimeter Only On and Auto Partial On time by one hour using the ExtendAuto On Time function ([#][5][1]). When [#][5][1] is entered, the control panel sends an Auto On Extended {21}report.Users can also change Skeds using the Change Skeds function ([#][5][2]). A Sked must first be entered before theChange Skeds function is used.The following sections and parameters detail the programming of each of the eight Skeds. The parameters inOutput Parameters on page 85 determine the characteristics of the output activation that occurs at the Sked time.See Table 38 for Sked configuration parameter addresses.The default setting for all Sked parameters is 0 (zero).Table 38: Sked Configuration ParametersSked Type Assign(Area orOutput)Time(H _ _ _) (_H _ _) (_ _ M _) (_ _ _ M)Days 1OptionDays 2Option1 Addr 1184 Addr 1185 Addr 1186 Addr 1187 Addr 1188 Addr 1189 Addr 1190 Addr 11912 Addr 1192 Addr 1193 Addr 1194 Addr 1195 Addr 1196 Addr 1197 Addr 1198 Addr 11993 Addr 1200 Addr 1201 Addr 1202 Addr 1203 Addr 1204 Addr 1205 Addr 1206 Addr 12074 Addr 1208 Addr 1209 Addr 1210 Addr 1211 Addr 1212 Addr 1213 Addr 1214 Addr 12155 Addr 1216 Addr 1217 Addr 1218 Addr 1219 Addr 1220 Addr 1221 Addr 1222 Addr 12236 Addr 1224 Addr 1225 Addr 1226 Addr 1227 Addr 1228 Addr 1229 Addr 1230 Addr 12317 Addr 1232 Addr 1233 Addr 1234 Addr 1235 Addr 1236 Addr 1237 Addr 1238 Addr 12398 Addr 1240 Addr 1241 Addr 1242 Addr 1243 Addr 1244 Addr 1245 Addr 1246 Addr 1247Type, Sked #• Address: See Table 38• Default: 0 (No type assigned)• Selections:- 0 = No Type Assigned (Sked disabled)- 1 = Auto All On- 2 = Auto Perimeter Only On- 3 = Auto Partial On- 4 = Auto Off- 5 = Output On (DS7240V2: Outputs 1 to 15; DS7220V2: Outputs 1 to 12)- 6 = Output Off (DS7240V2: Outputs 1 to 15; DS7220V2: Outputs 1 to 12)The Sked Types "Output Function On" and "Output Function Off" override any output function at Sked time(except for Alarm Output Functions 1|8 to 1|12). For example, an output function that turns a light on isoverridden by a Sked that turns the same light on.Bosch Security Systems, Inc. | 2/09 | 4998153893-03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!