Chapter 5 - System Operation<br />
Typical Output Wiring Example<br />
<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>-Supplied Equipment<br />
XIO Connector – 26-Pin Female D-Sub<br />
Outputs 1-8<br />
+24VDC<br />
(equivalent<br />
circuit)<br />
Signal 0097<br />
19<br />
Signal 0098<br />
20<br />
Signal 0099<br />
21<br />
Signal 0100<br />
22<br />
Signal 0101<br />
23<br />
Signal 0102<br />
24<br />
Signal 0103<br />
25<br />
Signal 0104<br />
GND<br />
GND<br />
26<br />
1<br />
10<br />
User-Supplied Equipment<br />
Wiring<br />
Terminal<br />
Block<br />
Load<br />
Load<br />
Typical User Loads<br />
Load<br />
M<br />
M<br />
L<br />
N<br />
Customer<br />
AC Power<br />
Supply<br />
XIO Breakout Cable<br />
Figure 5-5. Typical User Wiring for XIO Output Signals<br />
The XIO Breakout cable is available as an option - see Figure 5-6. This cable connects to<br />
the XIO connector on the robot, and provides flying leads on the user’s end, for<br />
connecting input and output signals in the workcell. The part number for the cable is<br />
04465-000, and the length is 5 M (16.4 ft).<br />
See Table 5-8 on page 61 for the wire chart on the cable.<br />
NOTE: this cable is not <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>patible with the XIO Termination Block.<br />
Figure 5-6. Optional XIO Breakout Cable<br />
60 <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>s600</s<strong>tr</strong>ong>/<s<strong>tr</strong>ong>s800</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Robot</s<strong>tr</strong>ong> User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev C