Installing <s<strong>tr</strong>ong>Robot</s<strong>tr</strong>ong> Solenoid Kit<br />

12. Remove the four screws for the Joint 1 cover and lift the cover up so you have<br />

access to the tubing under the cover. See Figure 6-11.<br />

Joint 1 cover lifted to<br />

access spare air line<br />

User Air fitting for<br />

connecting spare line.<br />

Remove factory<br />

installed tubing first.<br />

Tubing bundle<br />

containing spare air<br />

line<br />

Figure 6-11. Connecting Spare Air Line to User Connector<br />

13. Disconnect the tubing from the 6mm User Air fitting shown in Figure 6-11. Fold<br />

the tubing out of the way and res<strong>tr</strong>ain using tie-wraps.<br />

14. Locate the spare air line contained in the tubing bundle inside the front end of the<br />

cover. Remove the spare air line from the bundle.<br />

15. Insert the spare air line into the back of the empty 6mm User Air fitting.<br />

NOTE: This 6mm User Air connector and the 6mm User Air connector at<br />

the top of Figure 6-2 on page 67 are not functional for other uses after this<br />

modification.<br />

16. Replace the Joint 1 cover, taking care to insure that all tubing is inside the cover<br />

and nothing gets crimped or pinched while pushing the cover into position.<br />

Replace four screws to secure the cover. Tighten the screws to 14 in-lbs of torque.<br />

17. Replace the cable s<strong>tr</strong>ap plate that you removed earlier in the procedure.<br />

18. Raise the AIB chassis to the closed position and tighten the securing screw.<br />

19. Replace the outer link cover and tighten the screws to 14 in-lbs of torque.<br />

20. Connect the factory air supply to the modified 6mm User Air connector.<br />

21. Turn on system power and boot the system. Once the system boot has <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pleted,<br />

at the V + dot prompt, type in the following <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mands to activate the solenoids<br />

one at a time.<br />

.Signal 3001<br />

.Signal 3002<br />

<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>s600</s<strong>tr</strong>ong>/<s<strong>tr</strong>ong>s800</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Robot</s<strong>tr</strong>ong> User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev C 77

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!