Installing Adjustable Hardstops<br />

8. In the next menu, enter the new value for the J2 upper limit softstop. See Table 6-7<br />

on page 88.<br />

9. Once you have modified the upper and lower joint limit softstops, you must save<br />

the new values. Select option 0 => Exit, then select option 7 = Save ALL<br />

specifications to system disk.<br />

10. Reboot the system by cycling 24VDC power to the SmartCon<strong>tr</strong>oller. The new joint<br />

limits will be in affect when the system reboot is done.<br />

<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>s600</s<strong>tr</strong>ong>/<s<strong>tr</strong>ong>s800</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Robot</s<strong>tr</strong>ong> User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev C 89