DSP402 standard configuration and adjustment parameters<br />

Code<br />

Description<br />

SPFd Parameter name: Speed setpoint factor denominator<br />

DSP402 name:<br />

DRIVECOM name:<br />

vl setpoint factor denominator<br />

Setpoint-Factor-Denominator<br />

Logic address: 8643 = 16#21C3 Type: INT<br />

CANopen index: 604B/2 Read/write: R/W<br />

INTERBUS index: 604B/2 Unit: -<br />

DeviceNet path: - Factory setting: 1<br />

Adjustment range -32768 ... -1; 1 ... 32767<br />

Parameter conforming to DSP402 profile.<br />

The speed setpoint factor is obtained by the )Divisor) and )Multiplier) parameters.<br />

These parameters have no unit and can take a value from -32768 to 32767, excluding value 0.<br />

The factor is used to modify the resolution or the direction of the setpoint. It is applied to the setpoint, and the references and<br />

output values of the speed function only.<br />

Reference:<br />

input<br />

numerator<br />

DIV<br />

MUL<br />

output<br />

denominator<br />

References and output values:<br />

input<br />

numerator<br />

MUL<br />

DIV<br />

output<br />

denominator<br />