Control parameters<br />

Code<br />

Description<br />

CMd Parameter name: Control word<br />

Terminal display:<br />

DSP402 name:<br />

DRIVECOM name:<br />

[Cmd value]<br />

controlword<br />

Control word<br />

Logic address: 8601 = 16#2199<br />

8501 = 16#2135 (1)<br />

Type:<br />

CANopen index: 6040 Read/write: R/W<br />

INTERBUS index: 6040<br />

DeviceNet path:<br />

8C/01/02<br />

Parameter conforming to DSP402 profile<br />

Possible values in IO profile<br />

On state command [2 wire] (2C)<br />

bit 0: Forward (on state) command<br />

= 0: No forward command<br />

= 1: Forward command<br />

The assignment of bit 0 cannot be modified. It corresponds to<br />

the assignment of the terminals. It can be switched.<br />

Bit 0 (Cd00) is only active if the channel of this control word<br />

is active.<br />

Bits 1 to 15 can be assigned to commands.<br />

WORD (bit register)<br />

On edge command [3 wire] (3C)<br />

bit 0: Stop (run authorization)<br />

= 0: Stop<br />

= 1: Run is authorized, on a forward or reverse<br />

command.<br />

bit 1: Forward (on 0 V 1 rising edge) command<br />

The assignment of bits 0 and 1 cannot be modified. It<br />

corresponds to the assignment of the terminals. It can be<br />

switched. Bits 0 (Cd00) and 1 (Cd01) are only active if the<br />

channel of this control word is active.<br />

Bits 2 to 15 can be assigned to commands.<br />

For example, to change the direction of operation using bit 2 of the control word of the active channel, simply configure the<br />

[Reverse assign.] (rrS) parameter:<br />

• to value [C102] (C102) ... [C402] (C402) for a fixed assignment<br />

• to value [CD02] (Cd02) for a switched assignment<br />

The stop commands:<br />

• Freewheel stop [Freewheel stop ass.] (nSt)<br />

• Fast stop [Fast stop assign.] (FSt) are active at value 0, in the same way as on the terminals.<br />

= 0: Stop<br />

= 1: No stop command<br />

DC injection braking [DC injection assign.] (dCI) is active at value 1, in the same way as on the terminals.<br />

= 0: No braking command<br />

= 1: Braking<br />

If a fixed assignment is made [C101] (C101) to [C115] (C115) ... [C401] (C401) to [C415] (C415), the freewheel stop, fast<br />

stop and DC injection braking commands are always active, even if the channel is not active. If these commands are<br />

configured as fixed assignments, the following settings must be made in order to start, even if another channel is active:<br />

• Freewheel stop = 1<br />

• Fast stop = 1<br />

• DC injection braking = 0<br />

If a switched assignment is made [CD00] (Cd00) to [Cd15] (Cd15) the freewheel stop, fast stop and DC injection braking<br />

commands are only active if the channel is active.<br />

(1) Both logical addresses may be used.<br />

If you need to access by Modbus messaging (function Modbus 16 = 16#10 Write Multiple Registers) to:<br />

- Control word,<br />

- Velocity setpoint,<br />

better use address 8601 for getting consecutive registers (the address of the setpoint is 8602).<br />

To access to:<br />

- Control word,<br />

- Frequency setpoint,<br />

better use address 8501 (the address of the setpoint is 8502).<br />

70