[1.4 MOTOR CONTROL] (drC-)<br />

Code<br />

Description<br />

LqS Terminal display: [Autotune L q-axis]<br />

Logic address: 9675 = 16#25CB Type: UINT<br />

CANopen index: 2042/4C Read/write: R/WS<br />

INTERBUS index: 5FC2/24 Unit: 0.01 mH<br />

DeviceNet path: 91/01/4C Factory setting: According to drive rating<br />

Adjustment range: 0 to 65,535<br />

Axis "q" stator inductance in mH.<br />

rSAS Terminal display: [Cust. stator R syn]<br />

Logic address: 9682 = 16#25D2 Type: UINT<br />

CANopen index: 2042/53 Read/write: R/WS<br />

INTERBUS index: 5FC2/27 Unit: According to drive rating (1)<br />

DeviceNet path: 91/01/53 Factory setting: According to drive rating<br />

Adjustment range: 0 to 65,535<br />

Cold state stator resistance (per winding)<br />

(1) According to drive rating<br />

If Power > 75 kW: Unit = 1 µΩ<br />

If Power ≤ 75 kW: Unit = 1 mΩ<br />