[1.4 MOTOR CONTROL] (drC-)<br />

Code<br />

Description<br />

Ubr Terminal display: [Braking level]<br />

Logic address: 14101 = 16#3715 Type: UINT<br />

CANopen index: 206F/2 Read/write: R/W<br />

INTERBUS index: 5FBF/B0 Unit: 1V<br />

DeviceNet path: A7/01/66 Factory setting: According to drive voltage (1)<br />

Adjustment range:<br />

According to drive voltage<br />

and line supply voltage<br />

DC bus voltage threshold above which the braking transistor cuts in to limit this voltage.<br />

bbA Terminal display: [Braking balance]<br />

Logic address: 14102 = 16#3716 Type: WORD (listing)<br />

CANopen index: 206F/3 Read/write: R/WS<br />

INTERBUS index: 5FBD/5F Factory setting: 0<br />

DeviceNet path:<br />

A7/01/67<br />

Function used to balance the braking power between the drives.<br />

0=[No] (nO): Function inactive<br />

1=[Yes] (YES): Function active<br />

(1) According to drive voltage<br />

ATV<strong>61</strong>pppM3X: Factory setting = 395<br />

ATV<strong>61</strong>pppN4: Factory setting = 785<br />