[1.6 COMMAND] (CtL-)<br />

Code<br />

Description<br />

rFC Terminal display: [Ref. 2 switching]<br />

Logic address: 8411 = 16#20DB Type: WORD (listing)<br />

CANopen index: 2036/C Read/write: R/WS<br />

INTERBUS index: 5FBC/A2 Factory setting: According to CFG and tCC (1)<br />

DeviceNet path:<br />

8B/01/0C<br />

0=[No] (nO): Not assigned<br />

96 = [ch1 active] (Fr1): No switching, [Ref.1 channel] (Fr1) active<br />

97 = [ch2 active] (Fr2): No switching, [Ref.2 channel] (Fr2) active<br />

129 = [LI1] (LI1)<br />

:<br />

142 = [LI14] (LI14)<br />

177 = [C101] (C101)<br />

:<br />

239 = [C415] (C415)<br />

See: “Assignment conditions for logic inputs and control bits”, page 181.<br />

• If the assigned input or bit is at 0, [Ref.1 channel] (Fr1) is active.<br />

• If the assigned input or bit is at 1, channel [Ref.2 channel] (Fr2) is active.<br />

Fr2 Terminal display: [Ref.2 channel]<br />

Logic address: 8414 = 16#20DE Type: WORD (listing)<br />

CANopen index: 2036/F Read/write: R/WS<br />

INTERBUS index: 5FBC/A5 Factory setting: According to CFG (2)<br />

DeviceNet path:<br />

8B/01/0F<br />

0=[No] (nO): Not assigned<br />

1=[AI1] (AI1): Analog input<br />

2=[AI2] (AI2): Analog input<br />

3=[AI3] (AI3): Analog input, if VW3A3202 extension card has been inserted<br />

4=[AI4] (AI4): Analog input, if VW3A3202 extension card has been inserted<br />

160 = [+/- speed] (UPdt): +/- speed command<br />

163 = [HMI] (LCC): Graphic display terminal<br />

164 = [Modbus] (Mdb): Integrated Modbus<br />

167 = [CANopen] (CAn): Integrated CANopen<br />

169 = [Com. card] (nEt): Communication card (if inserted)<br />

170 = [Prog. card] (APP): Controller Inside card (if inserted)<br />

181 = [RP] (PI): Frequency input, if VW3A3202 extension card has been inserted<br />

182 = [Encoder] (PG): Encoder input, if encoder card has been inserted<br />

COP Terminal display: [Copy channel 1 2]<br />

Logic address: 8402 = 16#20D2 Type: WORD (listing)<br />

CANopen index: 2036/3 Read/write: R/WS<br />

INTERBUS index: 5FBC/A0 Factory setting: 0<br />

DeviceNet path:<br />

8B/01/03<br />

0=[No] (nO): No copy<br />

1=[Reference] (SP): Copy reference<br />

2=[Command] (Cd): Copy command<br />

3=[Cmd + ref.] (ALL): Copy command and reference<br />

(1) According to CFG, see “CFG”, page 138 and tCC, see “tCC”, page 157.<br />

If CFG = 5 and tCC = 0, factory setting = [LI3] (LI3)<br />

If CFG = 5 and tCC = 1, factory setting = [LI4] (LI4)<br />

Otherwise, factory setting = 96<br />

(2) According to CFG, see “CFG”, page 138.<br />

If CFG = 5, factory setting = 1<br />

Otherwise, factory setting = 0<br />

184