Index of parameter INTERBUS addresses<br />

INTERBUS<br />

index<br />

Code Name Logic address<br />

CANopen<br />

index<br />

DeviceNet<br />

path<br />

Page<br />

5FC5/10 AO2C Physical image of analog output 2 5272 = 16#1498 2016/49 7B/01/49 91<br />

5FC5/11 AO3C Physical image of analog output 3 5273 = 16#1499 2016/4A 7B/01/4A 91<br />

5FC5/17 LFt <strong>Altivar</strong> fault code 7121 = 16#1BD1 2029/16 84/01/7A 94<br />

5FC5/18 CNFS [Config. Active] 8020 = 16#1F54 2032/15 89/01/15 81<br />

5FC5/18 CNFS Active configuration 8020 = 16#1F54 2032/15 89/01/15 63<br />

5FC5/19 CRC Active reference channel 8441 = 16#20F9 2036/2A 8B/01/2A 80<br />

5FC5/1A CCC Active command channel 8442 = 16#20FA 2036/2B 8B/01/2B 81<br />

5FC5/1C tUS [Auto tuning status] 9609 = 16#2589 2042/A 91/01/0A 144<br />

5FC5/1D rPE PID regulator discrepancy 11980 = 16#2ECC 2059/51 9C/01/B5 85<br />

5FC5/1E rPF PID regulator feedback reference 11981 = 16#2ECD 2059/52 9C/01/B6 85<br />

5FC5/1F rPC PID reference after ramp 11982 = 16#2ECE 2059/53 9C/01/B7 85<br />

5FC5/20 rPO PID regulator limit output reference 11983 = 16#2ECF 2059/54 9C/01/B8 85<br />

5FC5/21<br />

nM1<br />

Communication scanner, value of<br />

read word 1<br />

12741 = 16#31C5 20<strong>61</strong>/2A A0/01/8E 121<br />

5FC5/22<br />

nM2<br />

Communication scanner, value of<br />

read word 2<br />

12742 = 16#31C6 20<strong>61</strong>/2B A0/01/8F 121<br />

5FC5/23<br />

nM3<br />

Communication scanner, value of<br />

read word 3<br />

12743 = 16#31C7 20<strong>61</strong>/2C A0/01/90 121<br />

5FC5/24<br />

nM4<br />

Communication scanner, value of<br />

read word 4<br />

12744 = 16#31C8 20<strong>61</strong>/2D A0/01/91 121<br />

5FC5/25<br />

nM5<br />

Communication scanner, value of<br />

read word 5<br />

12745 = 16#31C9 20<strong>61</strong>/2E A0/01/92 121<br />

5FC5/26<br />

nM6<br />

Communication scanner, value of<br />

read word 6<br />

12746 = 16#31CA 20<strong>61</strong>/2F A0/01/93 121<br />

5FC5/27<br />

nM7<br />

Communication scanner, value of<br />

read word 7<br />

12747 = 16#31CB 20<strong>61</strong>/30 A0/01/94 122<br />

5FC5/28<br />

nM8<br />

Communication scanner, value of<br />

read word 8<br />

12748 = 16#31CC 20<strong>61</strong>/31 A0/01/95 122<br />

5FC5/29 CFPS Active parameter set 12900 = 16#3264 2063/01 A1/01/65 66<br />

5FC5/29 CFPS Active parameter set 12900 = 16#3264 2063/01 A1/01/65 81<br />

5FC8/01<br />

O01<br />

"Controller Inside" HMI exchange<br />

word 1<br />

6401 = 16#1901 2022/2 81/01/02 126<br />

5FC8/02<br />

O02<br />

"Controller Inside" HMI exchange<br />

word 2<br />

6402 = 16#1902 2022/3 81/01/03 126<br />

5FC8/03<br />

O03<br />

"Controller Inside" HMI exchange<br />

word 3<br />

6403 = 16#1903 2022/4 81/01/04 126<br />