Configuration saving and switching<br />

When the configuration or motor switching function is configured on inputs or on control word bits, to save a configuration that is already<br />

active, set bit 1 of the extended control word (CMI) to 1.<br />

Display<br />

terminal<br />

Current<br />

configuration<br />

(RAM)<br />

Modbus<br />

CANopen<br />

Network<br />

Industrial<br />

HMI terminal<br />

PLC<br />

Extended control word:<br />

Save configuration (CMI,1)<br />

Set to 1<br />

Active<br />

configuration<br />

(CNFS)<br />

1 2 3<br />

Configuration 0<br />

(EEPROM)<br />

Configuration 1<br />

(EEPROM)<br />

Configuration 2<br />

(EEPROM)<br />

Factory settings<br />

When the configuration or motor switching function is configured on inputs or on control word bits, bit 2 of the extended control word (CMI)<br />

must be set to 1.<br />

Display<br />

terminal<br />

Current<br />

configuration<br />

(RAM)<br />

Modbus<br />

CANopen<br />

Network<br />

Industrial<br />

HMI terminal<br />

PLC<br />

Extended control word:<br />

Restore configuration (CMI,2)<br />

Set to 1<br />

Active<br />

configuration<br />

(CNFS)<br />

1 2 3<br />

Configuration 0<br />

(EEPROM)<br />

Configuration 1<br />

(EEPROM)<br />

Configuration 2<br />

(EEPROM)<br />

Factory settings<br />

The configuration switching commands are only active if the drive is stopped, and not in "5-Operation enabled" state.<br />