Digital Programmer<br />

<strong>2704</strong> Controller<br />

6A. Chapter 6A DIGITAL PROGRAMMER<br />

6A.1. WHAT IS THE DIGITAL PROGRAMMER?<br />

The digital programmer provides a timed control of a single digital output. It may be used<br />

during any segment of a Setpoint Programmer or it may be used independently of the<br />

Setpoint Programmer.<br />

A sequence of eight Off <strong>and</strong> On times may be set for the output <strong>and</strong> up to four Digital<br />

Programs can be set. Figure 6-4 shows an example of a timed digital output program.<br />

On<br />

On 1 On 2 On 3 On 4 On 8<br />

Off<br />

Off 1 Off 2 Off 3 Off 8<br />

Figure 6A-1: An Example of a Programmed Digital Output<br />

Time<br />

Step Time Description<br />

On 1 1:00:00.0 On starting the sequence the output will be ON for 1 hour<br />

Off 1 0:30:00.0 The output switches OFF for 30 minutes<br />

On 2 0:05:00.0 The output switches ON for 5 minutes<br />

Off 2 0:30:00.0 The output switches OFF for 30 minutes<br />

On 3 1:00:00.0 The output switches ON for 1 hour<br />

Off 3 0:25:00.0 The output switches OFF for 25 minutes<br />

On 4 0:10:00.0 The output switches ON for 10 minutes<br />

Off 4 0:00:00.0<br />

On 5 0:00:00.0<br />

Off 5 0:00:00.0 The step is omitted for any time set to zero<br />

On 6 0:00:00.0<br />

Off 7 0:00:00.0<br />

On 8 1:10:00.0 The output switches ON for 1 hour 10 minutes<br />

Off 8 0:40:00.0 The output switches OFF for 40 minutes <strong>and</strong> is then reset to the start<br />

of the sequence<br />

The sequence may be run by:<br />

1. Setting the ‘Run/Hold’ parameter to On<br />

2. From an external source such as a push-button switch wired to a digital input<br />

3. In any segment of a setpoint program if it has been wired, for example, to a Programmer<br />

User Value.<br />