<strong>2704</strong> Controller<br />

4. Chapter 4 ACCESS LEVELS<br />

Parameters are protected under five different levels of access for which security codes may be<br />

necessary. This chapter describes the different levels of access to the operating parameters<br />

available in the <strong>controller</strong>.<br />

4.1. THE DIFFERENT ACCESS LEVELS<br />

Access Level What you can do Password<br />

Protection<br />

Level 1 This is sometimes referred to as Operator Level since it allows<br />

operators to view <strong>and</strong> adjust parameters within limits set in<br />

higher levels. Any page available in levels 2 or 3 may be<br />

configured to appear in level 1. This is done from the<br />

configuration level using the page promote feature, see<br />

Engineering Manual HA026933<br />

No<br />

Level 2<br />

Level 3<br />

Config<br />

View Config<br />

This is sometimes referred to as Supervisor level since all the<br />

parameters relevant to a particular configuration are visible. All<br />

alterable parameters can be adjusted.<br />

These are parameters which are generally required when<br />

commissioning the <strong>controller</strong>. Any page at this level can also<br />

be configured to appear at Level 2.<br />

This special level allows access to configure the fundamental<br />

characteristics of the <strong>controller</strong> <strong>and</strong> is not included in this<br />

operating h<strong>and</strong>book.<br />

For configuration details see <strong>2704</strong> Engineering Manual Part no<br />

HA026933<br />

This is a read only level which allows you to view the<br />

configuration of the <strong>controller</strong>. It is not possible to change<br />

parameter values in this level. It is not possible to read<br />

passcodes in this level.<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

4.2. PASSCODES<br />

On switch on the <strong>controller</strong> defaults to Level 1 which is not protected by a passcode. A<br />

limited set of parameters can be changed in this level. The parameter tables in each chapter<br />

list those parameters which can be changed.<br />

Level 2, level 3 <strong>and</strong> Configuration level are protected by passcodes. The default passcodes<br />

set in a new <strong>controller</strong> are:<br />

Level 2 Passcode ‘2’<br />

Level 3 Passcode ‘3’<br />

View Config Passcode <strong>2704</strong><br />

These passcodes can only be changed in configuration level.<br />

See Engineering Manual HA026933.<br />

4-2 Installation <strong>and</strong> Operation H<strong>and</strong>book. Part No HA026502 Issue 1.0 Apr-00