<strong>2704</strong> Controller Getting Started<br />

3.3. THE PROG BUTTON<br />

If the <strong>controller</strong> is configured as a programmer this button has three functions:<br />

• To put the programmer into RUN mode. This causes the working setpoint to follow the<br />

profile set in the program being used.<br />

• To put the programmer into HOLD mode. This stops the program from running <strong>and</strong><br />

maintains the setpoint at the current level..<br />

• To put the programmer into RESET mode. This resets the programmer to the <strong>controller</strong><br />

setpoint, the working setpoint can be changed manually using the Raise/Lower buttons.<br />

This button operates all programmer setpoints simultaneously.<br />

3.4. THE LOOP SELECT BUTTON<br />

If more than one loop is configured, the Loop Select button allows you to select a summary<br />

of each loop from whatever page is being displayed at the time. Each press of the Loop<br />

Select button will change the display from the ‘ALL LOOPS’ view to ‘Loop 1’ summary to<br />

the ‘Loop 1 Trend’ chart, followed by the next loop summary, <strong>and</strong> so on.<br />

By default a loop is designated by the mnemonic ‘LP’ followed by the loop number (1, 2 or<br />

3). This is shown in the banner at the top of the display page. The default message may be<br />

replaced by a customised name for the loop.<br />

To return to the original page view at any time, press the page button, . Alternatively, a<br />

timeout may have been set which will return the display to the HOME page view after a set<br />

period. The timeout is set in configuration level, see Engineering Manual part no HA026933.<br />

If only one loop is configured the display toggles between ‘LP1’ <strong>and</strong> ‘LP1 Trend’, (the ‘ALL<br />

LOOPS’ page is not shown).<br />

Press<br />

LOOP<br />

Press<br />

LOOP<br />

Next Loop<br />

Summary<br />

Back to ALL<br />

LOOPS summary<br />

Figure 3-3: Loop Summary <strong>and</strong> Loop Trend Chart<br />

Installation <strong>and</strong> Operation H<strong>and</strong>book. Part No HA026502 Issue 1.0 Apr-00 3-5