05.06.2015 Views

model 2704 controller installation and operation handbook - Soliton

model 2704 controller installation and operation handbook - Soliton

model 2704 controller installation and operation handbook - Soliton

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>2704</strong> Controller Programmer Operation<br />

CourseHbk PSP2 Range displayed if HBk<br />

Type _ Off<br />

PSP3 Hbk<br />

Type<br />

PSP3<br />

FineHbk<br />

PSP3<br />

CourseHbk<br />

PSP3 Hbk<br />

Value<br />

Hot Start<br />

PSP<br />

Rate Units<br />

Prog Cycles<br />

End Action<br />

Program<br />

Name<br />

Holdback type for PSP3<br />

These are deviation<br />

values between setpoint<br />

<strong>and</strong> process value.<br />

Fine <strong>and</strong> course holdback<br />

allows two levels of<br />

holdback to be applied to<br />

different segments.<br />

Fine holdback value for<br />

PSP3<br />

Course holdback value for<br />

PSP3<br />

Holdback value for PSP3<br />

Allows hot start to be<br />

applied to each PSP.<br />

See also 6.3.5.<br />

Rate units for a Ramp<br />

Rate Programmer<br />

Sets the number of times<br />

the complete program is<br />

executed.<br />

Defines the action in the<br />

end segment.<br />

Dwell - the program will<br />

dwell indefinitely at the<br />

conditions set in the end<br />

segment.<br />

Reset - the program will<br />

reset to the start<br />

conditions.<br />

Allows a user defined<br />

name to be given to the<br />

program number<br />

Off<br />

Fine Lo<br />

Fine Hi<br />

Fine B<strong>and</strong><br />

Course Lo<br />

Course Hi<br />

Course Bnd<br />

Display<br />

Range<br />

Display<br />

Range<br />

SP1 hi limit<br />

to<br />

SP1 lo limit<br />

None<br />

PSP1<br />

PSP2<br />

PSP3<br />

Per Second<br />

Per Minute<br />

Per Hour<br />

Continuous<br />

to 999<br />

Dwell<br />

Reset<br />

User string<br />

Off<br />

L1<br />

0 L3. Only<br />

displayed if HBk<br />

Type _ Off<br />

0 L3. Only<br />

displayed if HBk<br />

Type _ Off<br />

0 L3<br />

None<br />

Continuous<br />

L3. Only<br />

appears if Hot<br />

Start option has<br />

been enabled in<br />

config level.<br />

L3. Only<br />

displayed if the<br />

programmer is<br />

Ramp Rate<br />

L1<br />

L1<br />

L1<br />

Installation <strong>and</strong> Operation H<strong>and</strong>book. Part No HA026502 Issue 1.0 Apr-00 6-19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!