Controller Applications<br />

<strong>2704</strong> Controller<br />

10.2.1. Zirconia Parameters<br />

Table Number:<br />

10.2.1.<br />

This table allows you to view or adjust<br />

zirconia probe parameters<br />

ZIRCONIA PROBE<br />

(Options Page)<br />

Parameter Name Parameter Description Value Default Access<br />

Level<br />

Zirconia Value<br />

Zirconia control process<br />

value<br />

The O2 or dew point value<br />

derived from temperature<br />

<strong>and</strong> remote gas reference<br />

inputs<br />

Range units<br />

H-CO Reference Gas reference 0.0 to 999.0 20.0 L3<br />

Rem Gas Ref IP Remote gas reference 0.0 to 999.0 L3<br />

Enable Rm H-CO<br />

Working H-CO<br />

Process Factor<br />

Remote gas enable.<br />

This can be an internal<br />

value from the user interface<br />

or remote from an external<br />

source.<br />

Working gas reference or<br />

process factor<br />

Process Factor is used in<br />

some zirconia probes to<br />

provide compensation for<br />

the varying abilities of<br />

different alloys to absorb<br />

carbon.<br />

Clean Mode Zirconia clean probe input Off<br />

On<br />

Clean Freq<br />

Zirconia probe cleaning<br />

interval<br />

Internal<br />

Remote<br />

Internal<br />

R/O<br />

L3<br />

0.0 to 999.0 L3 R/O<br />

0.0 to 999.0 L3<br />

Off to<br />

99:54:00.0<br />

Clean Duration Sets the cleaning time 0:00:06.0 to<br />

1:39:54.0<br />

Max Recvy Time<br />

Min Recvy Time<br />

Min Cal Temp<br />

Maximum recovery time<br />

after purging<br />

Minimum recovery time after<br />

purging<br />

Minimum calculation temp.<br />

Sets the minimum<br />

temperature at which the<br />

calculation takes place<br />

0:00:06.0 to<br />

0:10:00<br />

Off to 0:00:01<br />

to 0:10:00<br />

Off<br />

4:00:00:<br />

0<br />

0:10:00:<br />

0<br />

0:10:00:<br />

0<br />

0:10:00:<br />

0<br />

L3<br />

L3<br />

L3<br />

L3<br />

L3<br />

-999.0 L3<br />

Probe Offset Zirconia mV offset to 0.0 L3<br />

Temp Offset Sets the temperature offset 2000.0 0.0 L3<br />

10-6 Installation <strong>and</strong> Operation H<strong>and</strong>book. Part No HA026502 Issue 1.0 Apr-00