05.06.2015 Views

model 2704 controller installation and operation handbook - Soliton

model 2704 controller installation and operation handbook - Soliton

model 2704 controller installation and operation handbook - Soliton

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Programmer Operation<br />

<strong>2704</strong> Controller<br />

Wait Status Wait Status No Wait<br />

Event A<br />

Event B<br />

Event C<br />

Wait Condition<br />

Wait condition for the running<br />

segment<br />

No Wait<br />

Event A<br />

Event B<br />

Event C<br />

No Wait<br />

R/O<br />

No Wait L1.<br />

Alterable in<br />

Hold<br />

Prog User Val 1 Active Programmer User Val 1 L1<br />

Prog User Val 2 Active Programmer User Val 2 L1<br />

Goback Rem Number of repeat cycles<br />

remaining<br />

1 to 999 R/O<br />

End Action<br />

Prog Reset DO<br />

The state required in the end<br />

segment<br />

These are the digital events in<br />

Reset<br />

æ æ æ æ<br />

Dwell<br />

Reset<br />

Reset UsrVal1 Reset prog user 1 values L3<br />

Reset UsrVal1 Reset prog user 1 values L3<br />

R/O<br />

R/O<br />

Only if<br />

configured.<br />

Table Number:<br />

6.6.5b<br />

These parameters are associated with<br />

Profiled Setpoint number 1<br />

PROGRAM RUN<br />

(PSP1 Page)<br />

Parameter Name Parameter Description Value Default Access<br />

Level<br />

Seg Time Rem Segment time remaining h: m: s<br />

PSP1 Type<br />

PSP1 WSP<br />

Running segment type for<br />

profiled setpoint 1<br />

Working setpoint for profiled<br />

setpoint 1<br />

Step<br />

Dwell<br />

Ramp<br />

Display<br />

range 1<br />

R/O - shown<br />

in Ramp<br />

Rate prog.<br />

L1. Alterable<br />

in Hold<br />

PSP1 Target<br />

Running segment target for<br />

profiled setpoint 1<br />

Display<br />

range 1<br />

L1. Alterable<br />

in Hold<br />

PSP1 Dwell Tm<br />

Time remaining in running<br />

segment for profiled SP 1<br />

Display<br />

range<br />

L1. Alterable<br />

in Hold<br />

PSP1 Rate<br />

Running segment rate for<br />

profiled setpoint 1<br />

Display<br />

range 1<br />

L1. Not in<br />

Time To<br />

Target prog<br />

PSP1 HBk Appl<br />

Holdback applied for profiled<br />

setpoint 1<br />

No<br />

Yes<br />

R/O - shown<br />

if configured<br />

1. Range limited by user defined upper <strong>and</strong> lower limits<br />

Table 6.6.5b is repeated for PSP2 parameters <strong>and</strong> PSP3 parameters<br />

6-16 Installation <strong>and</strong> Operation H<strong>and</strong>book. Part No HA026502 Issue 1.0 Apr-00