3.12 NAVIGATION DIAGRAM<br />

INSTRUMENT<br />

SUMMARY<br />

PROGRAM MIMIC<br />

PROGRAM RUN<br />

PROGRAM EDIT<br />

Options<br />

Units<br />

Display<br />

Page Prom<br />

User Text<br />

Summary<br />

St<strong>and</strong>by<br />

Select<br />

using<br />

or<br />

S01/04<br />

1372<br />

1000<br />

-200<br />

General<br />

PSP1<br />

PSP2<br />

PSP3<br />

Select<br />

using<br />

or<br />

Options<br />

Wiring<br />

Program<br />

Segment<br />

Select<br />

using<br />

or<br />

Parameters for<br />

Access<br />

See Chapter 4<br />

Parameters for<br />

Instrument<br />

See Eng. Manual<br />

HA026933<br />

Parameters for<br />

Summary<br />

See Chapter 5<br />

Parameters for<br />

Program Run<br />

See Chapter 6<br />

Parameters for<br />

Program Edit<br />

See Chapter 6<br />

DIGITAL PROG<br />

ALARMS<br />

AUTOTUNE<br />

LP 1 SETUP<br />

LP 2 SETUP<br />

LP 3 SETUP<br />

ZIRCONIA PROBE<br />

Go To<br />

Humidity<br />

Dig Prog 1<br />

Dig Prog 2<br />

Dig Prog 3<br />

Dig Prog 4<br />

Edit Program<br />

Parameters for<br />

Digital Program<br />

See Chapter 6A<br />

Select<br />

using<br />

or<br />

Summary<br />

LP1 (to 3)<br />

PV Input<br />

AN Input<br />

Module 1 (to 6)<br />

User 1 (to 8)<br />

Parameters for<br />

Alarms<br />

See Chapter 7<br />

Select<br />

using<br />

or<br />

Parameters for<br />

Autotune<br />

See Chapter 8<br />

Options<br />

Wiring<br />

SP<br />

SP (Aux)<br />

Cascade<br />

Ratio<br />

Override<br />

PID<br />

PID (Aux)<br />

Motor<br />

Output<br />

Diagnostic<br />

Display<br />

Display (Aux)<br />

Load Sim<br />

Select<br />

using<br />

or<br />

Notes:<br />

Parameters for Loop 2 <strong>and</strong> Loop 3 Set up<br />

See Chapter 9<br />

Options<br />

Wiring<br />

Parameters for<br />

Zirconia Probe<br />

See Chapter 10<br />

1. Page headers shown shaded are only available in Config <strong>and</strong> View Config level<br />

Parameters for<br />

LP 1 Setup<br />

See Chapter 9<br />

2. Text shown in italics is user configurable in configuration mode <strong>and</strong> may be<br />

different from that shown<br />

3-20 Installation <strong>and</strong> Operation H<strong>and</strong>book. Part No HA026502 Issue 1.0 Apr -00