Getting Started <strong>2704</strong> Controller<br />

3.10. PARAMETER TABLES<br />

Subsequent chapters in this manual refer to parameter tables. These tables provide the full<br />

list of parameters available at Access Level 3 in a particular page. The table below is an<br />

example.<br />

Column 1 gives the name of the parameter as it appears on the display.<br />

Column 2 is a description <strong>and</strong> possible usage of the parameter<br />

Column 3 is the range of values which can be set. . This may be a numerical value, eg -n<br />

to +n, or the condition (enumeration) of a parameter, eg the parameter ‘Program<br />

Status’ has enumerations ‘Run’, ‘Hold’, ‘Reset’.<br />

Column 4 is the default value (if applicable) of the parameter set during manufacture<br />

Column 5 is the access level required to change the parameter value.<br />

L1 means that the value is only shown in Level 1<br />

L2 means that the value is only shown in Level 1 <strong>and</strong> Level 2<br />

L3 means that the value is always available in the instrument operating mode<br />

(i.e. not Configuration Level)<br />

R/O is Read Only<br />

Access Levels are described in Chapter 4.<br />

For Configuration Level access see <strong>2704</strong> Engineering Manual, Part Number HA<br />

026933<br />

Table Number: Description of the page Page<br />

Header<br />

1<br />

Parameter Name<br />

2<br />

Parameter Description<br />

3<br />

Value<br />

4<br />

Default<br />

5<br />

Access<br />

Level<br />

Program Number The number of the selected program L3<br />

Segment Number The currently running segment<br />

number<br />

L3<br />

PSP1 Type Program Setpoint 1 type L3<br />

PSP1 Working SP Program Setpoint 1 working setpoint L3<br />

PSP1 Target Program Setpoint 1 target setpoint L3<br />

PSP1 Dwell Time Program Setpoint 1 dwell time L3<br />

This is a continuous loop which returns to the list header<br />

Note:-<br />

A parameter only appears if it is relevant to the configuration of the <strong>controller</strong>. For<br />

example, a programmer configured as Time to Target will not display the Rate<br />

parameter.<br />

3-14 Installation <strong>and</strong> Operation H<strong>and</strong>book. Part No HA026502 Issue 1.0 Apr-00