11.07.2015 Views

V6 User Manual 1.00.book - Studio General

V6 User Manual 1.00.book - Studio General

V6 User Manual 1.00.book - Studio General

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Cue Sequencer ControlThe Cue Sequencer is controlled the following way:Safe Mode:Reset Show:Stop Show:Start Show:Previous:Next:GO !:When in safe mode, the Cue Sequencer window is maximized and all Keyboardshortcuts except those related to the Cue Sequencer are disabled. The CueSequencer TimeCode counter is colored in red when not in Safe Mode.All Cues have to be reset before starting to play the sequence. When pressing thisbutton all Cues are reset to the Ready State (Pink Color) and the time is reset to00:00:00:000.To Stop the sequence playoutTo Start the sequence playout.To set the focus to the previous Cue.To set the focus to the Next Cue.To Start the currently selected Cue and select the next one.Appendix VI 9 - Pin connectionPC RS-232 Serial Port to External Sony P2 RS-422 ControllerThe RS-232 ports of a standard PC are slightly different from the RS-422 format used for the Sony P2 protocol. Werecommend the use of an external RS-232/RS-422 adapter. One example is the Antona ANC 6090 which can beordered from your Merging sales representative under the item number MRS422. This adapter is intended to beconnected directly to the serial port of your PC (either COM1 or COM2) with the other end used to connect a standardSony P2 RS-422 cable. As both connectors on the adapter are Female DB9, beware of the orientation andplease check that the printed indication "RS-232" is connected to the PC COM port.Connecting an RS422 device using a direct cable(without RS-232 / RS-422 adapter)For emergency use and for short distances, a direct cable may be used. However, Merging Technologies does notguarantee the correct function of an external controller if this cable is used. Different cables are required dependingon whether Pyramix is controlled by a master device or is controlling a slave device.Direct Cable for a Master DeviceThis pinout should work in most of the cases where Pyramix is controlled by a Master device (check on your controllerif the RS422 connector has to be male or female). It has been tested with various mixers such as Sony DMX-R100, Soundcraft Spirit, Soundtracs DPC II and DS3, and various other Sony P2 protocol capable controllers:RS422 Male (or Female) DB9RS232 Female DB9FunctionPin #Pin #FunctionGNDRcv -Xmit +GNDN.C.GNDRcv +Xmit -GND123456789123456789DCD/RLSDRxTxDTRGNDDSRRTSCTSRIShieldShieldRS422 DIrect Cable for Master Device pinoutsAppendices : Appendix VI 9 - Pin connection 29 - 576

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!