Wait States<br />

Control Program (<strong>CP</strong>) Enabled <strong>and</strong> Disabled<br />

<strong>CP</strong> enters both enabled <strong>and</strong> disabled wait states. <strong>CP</strong> enters an enabled wait state<br />

when it is waiting for work. <strong>CP</strong> enters a disabled wait state when system operation<br />

is terminated due to an error or when system shutdown is complete. z/<strong>VM</strong> service<br />

programs, such as H<strong>CP</strong>LDR, enter a disabled wait state when they terminate.<br />

When <strong>CP</strong> or one of its service programs enters a disabled wait state, it loads a wait<br />

state code into the program status word (PSW). The PSW is 16 hexadecimal digits<br />

long. This PSW will appear on the operator’s console, at the end of the wait state<br />

message you receive.<br />

Where to Find the Disabled Wait State Code<br />

For a description of what the disabled wait state code means <strong>and</strong> suggested<br />

actions to take, look up the <strong>CP</strong> message that has the same number as the wait<br />

state code. The format of the disabled wait state PSW is shown below:<br />

xxxxyyyy zzzzwwww<br />

where:<br />

xxxx 000A - a disabled wait state<br />

yyyy 0000<br />

zzzz 0000<br />

wwww<br />

is the disabled wait state code. This disabled wait state code is a <strong>CP</strong><br />

message number except for the following situations:<br />

Wait States<br />

1. <strong>CP</strong> loads wait state 0FFF after shut down when either a timeout is<br />

specified for SHUTDOWN or the default signal timeout is not zero. The<br />

default signal timeout is set with the SET SIGNAL SHUTDOWNTIME<br />

comm<strong>and</strong> or system configuration file statement.<br />

2. The operator specifies the wait state code by using the WAIT oper<strong>and</strong><br />

on the SHUTDOWN comm<strong>and</strong>. The WAIT oper<strong>and</strong> allows any hex<br />

value from 0000 to FFFF.<br />

Chapter 2. <strong>System</strong> <strong>Codes</strong> 133