H<strong>CP</strong>2271I H<strong>CP</strong>2276I<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

Operator Response: None.<br />

H<strong>CP</strong>2271I rdev DASD fast write deactivate<br />

pending.<br />

Explanation: The device has reported the following<br />

state change:<br />

DASD fast write entered the PEND (SC) state<br />

This Indicates a destage of DASD fast write data has<br />

either failed or is in the process of being destaged.<br />

The rdev variable identifies the device reporting the<br />

state change.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

Operator Response: Contact your system support<br />

personnel if DASD fast write destage has failed.<br />

Programmer Response: If DASD fast write destage<br />

has failed, examine the EREP outboard recorder (OBR)<br />

record for additional details of the failure. Refer to the<br />

hardware <strong>System</strong> Reference Library (SRL) manuals for<br />

sense data format <strong>and</strong> descriptions. If a hardware<br />

problem is indicated, contact the appropriate hardware<br />

service personnel.<br />

H<strong>CP</strong>2272I rdev DASD fast write function is<br />

inactive.<br />

Explanation: The device has reported the following<br />

state change:<br />

DASD fast write entered the INACTIVE state<br />

indicating that the DASD fast write function has been<br />

turned off.<br />

The rdev variable identifies the device reporting the<br />

state change.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

Operator Response: None.<br />

H<strong>CP</strong>2273I rdev Subsystem cache is available.<br />

Explanation: The device has reported the following<br />

state change:<br />

Subsystem cache entered the ACTIVE state<br />

indicating that the subsystem cache is now available.<br />

The rdev variable identifies the device reporting the<br />

state change.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

Operator Response: None.<br />

278 z/<strong>VM</strong>: <strong>System</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong> — <strong>CP</strong><br />

H<strong>CP</strong>2274I rdev Subsystem cache destage is in<br />

progress.<br />

Explanation: The device has reported the following<br />

state change:<br />

Subsystem cache entered the PEND (SA) state<br />

indicating that the subsystem cache is currently<br />

transferring data to backing storage.<br />

The rdev variable identifies the device reporting the<br />

state change.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

Operator Response: None.<br />

H<strong>CP</strong>2275I rdev Subsystem cache destage has<br />

failed.<br />

Explanation: The device has reported the following<br />

state change:<br />

Subsystem cache entered the PEND (SC) state<br />

indicating that a hardware failure occurred while<br />

attempting to transfer data from cache to backing<br />

storage.<br />

The rdev variable identifies the device reporting the<br />

state change.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

Operator Response: Contact your system support<br />

personnel.<br />

Programmer Response: Examine the EREP outboard<br />

recorder (OBR) record for additional details of the<br />

failure. Refer to the hardware <strong>System</strong> Reference Library<br />

(SRL) manuals for sense data format <strong>and</strong> descriptions.<br />

If a hardware problem is indicated, contact the<br />

appropriate hardware service personnel.<br />

H<strong>CP</strong>2276I rdev Subsystem cache has failed.<br />

Explanation: The device has reported the following<br />

state change:<br />

Subsystem cache entered the FAILED state<br />

indicating that the subsystem cache has failed because<br />

of hardware errors.<br />

The rdev variable identifies the device reporting the<br />

state change.<br />

<strong>System</strong> Action: <strong>System</strong> operation continues.<br />

Operator Response: Contact your system support<br />

personnel.<br />

Programmer Response: Examine the EREP outboard<br />

recorder (OBR) record for additional details of the<br />

failure. Refer to the hardware <strong>System</strong> Reference Library<br />

(SRL) manuals for sense data format <strong>and</strong> descriptions.<br />

If a hardware problem is indicated, contact the<br />

appropriate hardware service personnel.