H<strong>CP</strong>721E H<strong>CP</strong>729I<br />

PRINTR<br />

The CMS return code plus 100<br />

WAITRD<br />

The CMS return code plus 200<br />

RDBUF<br />

The CMS return code plus 300<br />

TYPE or TYPLIN<br />

The CMS return code plus 400<br />

<strong>System</strong> Action: If the input is from cards or a CMS<br />

file, the program terminates after scanning the<br />

remaining statements for syntax. Otherwise, the<br />

program is immediately terminated.<br />

User Response: Correct the error as indicated by the<br />

return code, <strong>and</strong> resubmit the job.<br />

H<strong>CP</strong>721E RECORD cchhr NOT FOUND<br />

Explanation: The record indicated by cchhr was not<br />

found. The cchhr refers to the address (cylinder, head,<br />

<strong>and</strong> record) of the record explicitly described by the<br />

PRINT or TYPE function.<br />

<strong>System</strong> Action: The system terminates the PRINT or<br />

TYPE function in process <strong>and</strong> continues; the remaining<br />

job steps are unaffected.<br />

User Response: If the explicit record identifier is not<br />

known, print or type on a cylinder or track basis.<br />

H<strong>CP</strong>725D SOURCE DASD DEVICE WAS (IS)<br />

LARGER THAN OUTPUT DEVICE.<br />

Explanation:<br />

DO YOU WISH TO CONTINUE?<br />

RESPOND YES OR NO:<br />

For the RESTORE function-<br />

The number of cylinders on the original DASD<br />

input unit contained more cylinders than the<br />

output device.<br />

For the COPY function-<br />

The input device contains more cylinders than<br />

the output device.<br />

<strong>System</strong> Action: <strong>System</strong> waits for user’s response.<br />

User Response: Determine if the copy or restore<br />

function is to continue; respond either YES or NO.<br />

Note: This message is issued when the PROMPTS ON<br />

processing control statement is in effect, which is<br />

the default. If PROMPTS OFF was in effect,<br />

message H<strong>CP</strong>699I would be issued in place of<br />

this message. For more information on H<strong>CP</strong>699I,<br />

see page 195.<br />

200 z/<strong>VM</strong>: <strong>System</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong> — <strong>CP</strong><br />

H<strong>CP</strong>726E MOVING DATA INTO ALTERNATE<br />

TRACK CYLINDER(S) IS PROHIBITED<br />

Explanation: An extent statement was encountered<br />

that attempted to either RESTORE or COPY a cylinder<br />

of data into the alternate track cylinder. This is not<br />

permitted. Use the alternate track cylinders of disks only<br />

for alternate tracks <strong>and</strong> not as primary data area.<br />

<strong>System</strong> Action: The program attempts to read<br />

another control statement or to read another EXTENT<br />

statement.<br />

Operator Response: If the EXTENT statement<br />

contains a typographical error, correct it. Otherwise, find<br />

some other cylinders to restore or copy the data to. The<br />

REORDER oper<strong>and</strong> of the EXTENT statement can be<br />

used to move an entire minidisk to different cylinders.<br />

User Response: None.<br />

Programmer Response: None.<br />

H<strong>CP</strong>728E DECODE ERROR ENCOUNTERED: nn<br />

Explanation: DDR is unable to exp<strong>and</strong> data from<br />

compact format when restoring to DASD from tape. nn<br />

is the return code from the decoding routing.<br />

The return codes are as follows:<br />

Code Meaning<br />

2 The first byte of input contains 0 or a number<br />

greater than 5. This should not occur. It may<br />

be caused by using a set of encoding tables<br />

that do not match the decoding tables that are<br />

supplied.<br />

3 There is more data to be decoded, but the<br />

output buffer is not big enough to hold more.<br />

Decoding stopped when the output buffer<br />

became full.<br />

4 The decoding tables are malformed, or the<br />

compacted data was incorrectly transmitted.<br />

The program tried to decode a codeword that<br />

could not be decoded within its first 21 bits.<br />

5 The exp<strong>and</strong>ed data is not the same length as<br />

the original data.<br />

<strong>System</strong> Action: The program ends.<br />

User Response: Recreate the input. If this is not<br />

possible, call your system support personnel.<br />

H<strong>CP</strong>729I FULL TRACK READ NOT AVAILABLE<br />

Explanation: The FTR keyword has been requested<br />

on the DDR DUMP control statement, but the FTR<br />

hardware feature is not available.<br />

<strong>System</strong> Action: The FTR keyword is ignored <strong>and</strong> the<br />

output dump tape is created in 4KB block format.<br />

User Response: None.